APPLICATION
The T8001F Thermostat provides single-stage, 
programmable temperature control for 24 Vac heating-
cooling systems with manual changeover from heat to 
cool. The T8024F Thermostat provides multistage 
electronic control of single-zone heating and cooling 
systems. Heating cycle rate is selectable at 1, 3, 4, 5, 6, 
9, or 12 cph. Cooling cycle rate is fixed at 3 cph. 
Temperature indication can be set for °F or °C. 
The T8001F, T8024F Thermostat is powered directly 
from the system transformer. Batteries are not required 
because setpoints are held permanently by non-volatile 
memory.
The T8001F, T8024F model includes a thermostat, 
wallplate and owner’s guide. See Table 1.
MERCURY NOTICE
If this control is replacing a control that contains 
mercury in a sealed tube, do not place your old 
control in the trash. Dispose of it properly.
Contact your local waste management authority 
for instructions regarding recycling and the 
proper disposal of the control. 
INSTALLATION
When Installing this Product…
1. Read these instructions carefully. Failure to follow 
them could damage the product or cause a hazard-
ous condition.
2. Check the ratings given in the instructions and on 
the product to make sure the product is suitable for 
your application.
3. Installer must be a trained, experienced service 
technician.
4. After installation is complete, check out product 
operation as provided in these instructions.
CAUTION
Hazardous Voltage.
Can damage heating/cooling system.
Disconnect power at furnace or main breaker/
fuse box.
Location
Install the thermostat about 5 ft (1.5m) above the floor in 
an area with good air circulation at average temperature. 
See Fig. 1. Do not install the thermostat where it can be 
affected by:
— drafts or dead spots behind doors and in corners.
— hot or cold air from ducts.
— radiant heat from the sun or appliances.
— concealed pipes and chimneys.
— unheated (uncooled) areas such as an outside wall 
behind the thermostat.
Installing Wallplate in Wall
IMPORTANT
Level only for appearance. The thermostat func-
tions normally even when not level.
Mount wallplate and the T8001F or T8024F with the wing 
anchors provided (see Fig. 2) as follows: 
1. Place the wallplate template at the desired location 
on the wall.
2. Trace and cutout the opening.
3. Pull the thermostat wire through the wallplate 
entrance hole.
4. Fasten the wallplate to the wall using the wing 
anchors.
Table 1. Thermostat Descriptions.
Model
System
Changeover
System Selection
Fan Selection
Powering Method
T8001F
Heat-Cool
Manual
Cool-Off-Heat
Auto-On
Hardwired
T8024F
Heat-Cool
Manual
Cool-Off-Heat
Auto-On
Hardwired