blue-seal e1100 Manuale Utente

Pagina di 41
-25- 
Revision 4/F3591 
© Moffat Ltd, August 2004 
8 Screws 
Locking Nut 
4)  Transfer  wires  to  the  new  timer  and  
reassemble in reverse order. 
Figure 6.3.8 
4) Replace  buzzer  and  re-assemble  in  
reverse order. 
1)  Remove the fan baffle (refer 6.2.2). 
2)  Remove the eight screws securing the fan 
and motor mounting plate situated at the 
oven rear.   
1)  Remove the fan baffle (refer 6.2.2). 
2)  Unscrew the glass cover (anti-clockwise). 
6.3.9  HOLD THERMOSTAT 
6.3.10  OVEN LIGHTS 
6.3.11  FAN / MOTOR 
Figure 6.3.9 
1)  Open  control  panel  (refer  6.2.1),  and  
remove right hand side panel. 
2)  Remove  the  hold  thermostat  knob  by  
pulling away from bracket. 
3)  Undo the two screws securing the hold 
thermostat to the bracket. 
4)  Remove fan baffle from inside oven (refer 
6.2.2). 
5)  Remove  the  two  screws  securing  the  
thermostat phial mounting bracket to the 
RH wall of the oven.  Feed the thermostat 
phial through into the control cavity.   
3) Replace  the  bulb  (40  watt  miniature  
Edison screw). 
Figure 6.3.12 
Figure 6.3.13 
1)  Remove R/H side panel (refer 6.2.4).   
2)  Disconnect wires from buzzer (secured to 
insulation panel).  
3)  Remove two screws securing the buzzer 
to its mounting bracket. 
6.3.8  BUZZER 
Two screws 
Figure 6.3.10 
Hold  
thermostat 
6)  Remove thermostat from oven.   
7)  Transfer  wires  to  new  thermostat  and  
reassemble with in reverse order. 
Glass cover 
Thermostat 
bulb 
Figure 6.3.11