blue-seal e1100 Manuale Utente

Pagina di 41
-27- 
Revision 4/F3591 
© Moffat Ltd, August 2004 
1)  Remove the right hand side panel (refer 
6.2.4). 
2)  Remove  the  two  screws  securing  the  
microswitch  bracket  to  the  insulation 
panel. 
6.3.17  DOOR MICROSWITCH 
Figure 6.3.25 
1)  Ensure water supply is turned off. 
2)  Remove the water injection nozzle from 
inside the oven (refer 6.3.19). 
3)  Remove the water solenoid access panel 
at the rear of the oven (4 screws). 
6.3.15  WATER SOLENOID VALVE 
1)  Remove water solenoid (refer 6.3.20). 
2)  Remove  the  two  screws  securing  the 
bracket to the solenoid. 
6.3.16  WATER SOLENOID CLEANING 
3)  Remove the valve assembly. 
4)  Clean the valve assembly, removing all 
dirt and grime from the valve seat. 
5) Reassemble  the  valve  assembly  and  
solenoid. 
Figure 6.3.23 
Figure 6.3.24 
Two Screws 
Figure 6.3.20 
4)  Remove the wires from the solenoid, and 
disconnect the mains water connection. 
5)  Remove  the  two  screws  securing  the  
solenoid bracket to the oven rear, and  
remove the valve assembly. 
Figure 6.3.21 
6)  On a suitable work surface, remove the 
brass  piping  connections  (½”  spanner) 
and two screws (on bracket) and extract 
the solenoid. 
7)  Secure  new  solenoid  with  screws  and  
reassemble.  Check that flow direction as 
marked on valve is correct. 
Brass  
Connections 
Two 
Screws 
Figure 6.3.22 
Water  
solenoid  
access panel