Honeywell CT3595 Manuale Utente

Pagina di 24
69-1199—4
8
STEP 4. WIRE WALLPLATE TERMINALS
IMPORTANT
All wiring must comply with local codes and ordinances. If unsure about household wiring procedures, call 
your local heating/air-conditioning contractor.
Refer to the labels you placed on the wires when you removed the 
old thermostat (see illustration).
q
Match the letter of your old thermostat wire with the 
corresponding terminal letter on your new thermostat. Refer to 
Table 2.
q
Remove the factory-installed jumper connecting terminals R and 
RC if wires are connected to both of those terminals.
q
For wiring diagrams, if needed, see pages 22-23.
q
Loosen the terminal screws. Slip each wire beneath its matching 
terminal. Wraparound and straight connections are both 
acceptable, (see illustration). Tighten the terminals.
q
Plug the hole in the wall with insulation to help prevent drafts 
from adversely affecting thermostat operation.
M16425
R
W
Y
G
M4826
FOR WRAPAROUND 
INSERTION STRIP 
7/16 IN. (11 MM).
FOR STRAIGHT INSERTION 
STRIP 5/16 IN. (8 MM).