2.3.2 OUTPUT DESCRIPTION
If any of the outputs is going to be connected to some highly inductive device,
a "1N4000" type diode must be installed in antiparallel. It is not required on
auxiliary relays of less than 20 mA.
The drives are enabled with auxiliary relays (section 5.2).
P I N
FUNCTION
5, 6, 7, 
24, 25, 26
Axis enable 
F A S T / S L O W  
DIRECTION PAR46
27
MANUAL mode
10
H output
Models A, A1, B 
Ram retraction. 
Section 2.3.4
Model A
Axes in position
Model A1
Approach and 
bending
Model B
Model B
Model A, A1, C
DESCRIPTION
Analog voltage 
outputs. PAR 64, 
P A R 6 5
18, 37
It activates the auxiliary output to raise the X axis backstop. R 
axis function, ON /OFF conditioned by the "H" editing attribute.
Enabling drives or frequency inverters for open loop control.
To control drives in closed loop drives.
When installing a pressure transducer or potentiometric scale, 
connect it to pin 18 and change the position of the internal 
jumper.
MANUAL mode selection confirmation.
SLOW approach. 
Section 2.3.4
A - Retraction control by trigger time of the thermostat 
conditioned by the "D" attribute.
Single output.
The FAST/SLOW change is handled with external resources 
from the electrical cabinet that manages the FAST  buttons and 
the change switch.
I15 when exceeding the bending pressure
29
9
I32 (A, A1) or Y = e (B, C) at the beginning of the bend if 
attribute B
A1, B - Forced retraction up to the top dead point. Bending time 
conditioned by the "D" attribute.
28
At all models, it is reset with :
It resets in the programmable change position that forces the 
slow motion output O29.
Fast movement 
handling. Ram 
approach.
Buzzer to warn the operator about "permission to bend"
Signal to the electrical cabinet to enable the FAST approach 
buttons or SLOW bend footswitch.