Chapter 2
Using Your 653X
© National Instruments Corporation
2-11
Figure 2-3.  Connecting Signals
If you are using the burst protocol, make the connection to the appropriate 
PCLK pin on the 653device.
Choosing the Startup Sequence
To avoid invalid or missing data when the ACK and REQ lines change 
polarity to either active-high or active-low, start a transfer using one of the 
following methods:
Control the configuration and use an initialization order.
Select compatible line polarities and default line levels.
Using an Initialization Order
This startup sequence ensures the 653 device is configured and is driving 
a valid ACK value before you enable the transfer on the peripheral device. 
Similarly, you can make sure the peripheral device is configured and is 
driving a valid REQ value before you enable the transfer on the 
653device:
1.
Configure the 653device for a mode compatible with your peripheral 
device.
2.
Configure and reset the peripheral device, if appropriate.
3.
Enable the input device (653device or peripheral device) and begin 
a transfer.
4.
Enable the output device (653device or peripheral device) and begin 
a transfer.
To control this initialization order, you need to enable and disable the 
peripheral device and control the order in which the 653device and the 
peripheral device are enabled. You can use the extra input and output lines 
for this purpose.
ACK
REQ
I/O
Confirm
Ready
I/O
653
X
 Device
Your Peripheral Device