Chapter 2
Using Your 653X
2-28
ni.com
The three types of trigger signals available are the start trigger, the stop 
trigger, or the start and stop trigger.
Start Trigger
A start trigger is a trigger that initiates a pattern I/O upon receipt of a 
hardware trigger on the ACK (STARTTRIG) pin.
Figure 2-16.  Starting Data Transfer Using a Trigger
Stop Trigger
When using a stop trigger, transfer starts upon a software command. Once 
a hardware trigger is received on the STOPTRIG pin, a predetermined 
amount of pretrigger and posttrigger data is saved in the buffer. Once this 
data is in the buffer, transfer stops. If the stop trigger arrives before all the 
pretrigger data is acquired an error will return in software.
Figure 2-17.  Stopping Data Transfer Using a Trigger
Start and Stop Trigger
When using a start and stop trigger, transfer starts upon receiving a trigger 
on the start trigger line (ACK/STARTTRIG pin) and ends upon receiving 
a trigger on the stop trigger line (STOPTRIG pin) and a predetermined 
amount of pretrigger and posttrigger data is saved in the buffer. If a stop 
trigger is received before a start trigger, it is ignored. If the stop trigger 
arrives before all the pretrigger data is acquired an error will return in 
software.
REQ
ACK (STARTTRIG)
Posttrigger Data
REQ
STOPTRIG
Pretrigger Data
Posttrigger Data