Zebra Technologies QL+ Manuale Utente

Pagina di 86
13
QL Series User Guide
Model UCLI72-4 Quad Charger
The UCLI72-4 Quad Charger is designed to charge up to four
QL Series battery packs simultaneously.  Batteries must be re-
moved from the printer to be charged in the Quad Charger.
1. Ensure that the charger has been installed properly per
the Quad Charger instruction manual.  Ensure that the power
indicator on the front panel is on.
2. Remove any protective shrink-wrap and labels from all
battery packs prior to use. Plug a battery pack into any one of
the four charging bays as shown in Figure 4, noting the orien-
tation of the battery pack. Slide the battery pack into the
charging bay until it stops.  Then rock the battery pack back
until it snaps into place. The amber indicator directly under the
battery being charged will turn on if the battery is properly in-
serted.
The indicators under the battery will allow you to monitor
the charging process per the table below:
Amber
Green
Battery Status
On
Off
Charging
On
Flashing
80% charged (O.K. to use)
Off
On
Completely Charged
Flashing
Off
Fault
 Note: A fault condition is caused by a problem with the
battery.  The charger may indicate a fault because the battery is
too hot or cold to charge reliably. Try to charge the battery again
when it returns to the room’s ambient temperature.  If the Amber
indicator starts flashing on the second attempt, the battery should
be discarded. Always dispose of batteries in a proper manner.
Refer to Appendix D.
Quad Charger Cycle Times :
Battery Status
QL 220/320
QL 420
Battery 80% Charged
1.25 Hrs.
2.5 Hrs.
Battery Fully Charged
2.5 Hrs.
5 Hrs.
 NOTE: These times are for completely discharged batteries.
continued