DMX Primer 
There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A 
fixture capable of receiving DMX 512 will require one or a number of sequential channels. The user 
must assign a starting address on the fixture that indicates the first channel reserved in the controller. 
There are many different types of DMX controllable fixtures and they all may vary in the total number 
of channels required. Choosing a start address should be planned in advance. Channels should 
never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is 
set incorrectly. You can however, control multiple fixtures of the same type using the same starting 
address as long as the intended result is that of unison movement or operation. In other words, the 
fixtures will be slaved together and all respond exactly the same.  
DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is 
where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which 
the fixtures are connected is not important and has no effect on how a controller communicates to 
each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures 
using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The 
shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET 
carries 3-pin XLR DMX compliant cables, DMX-
10 (33’), DMX-4.5 (15’) and DMX-1.5 (5’) 
 
S E T T I NG T HE   ST ART I NG   ADDRE S S  
This DMX mode enables the use of a universal DMX controller device. Each fixture requires a "start address" 
from 1 to 512. A fixture requiring one or more channels for control begins to read the data on the channel 
indicated by the start address. For example, a fixture that uses 6 DMX channels and was addressed to start on 
DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, and 105. Choose start addresses 
so that the channels used do not overlap, and note the start address selected for future reference.  
If this is your first time addressing a fixture using the DMX-512 control protocol, we suggest jumping to the 
Appendix Section and reading the heading “DMX Primer”. It contains very useful information that will help you 
understand its use.