Chauvet 250 Manuale Utente

Pagina di 20
 
 
 
 
Intimidator™ Spot LED 250 User Manual Rev. 11 
Page 9 of 20 
4.
 
O
PERATION
 
Control Panel 
Operation 
To access the control panel functions, use the four buttons located underneath the 
display.  
 
 
 
Button 
Function 
<MODE/ESC> 
Press to find an operation mode or to back out of the current menu 
option
 
<UP> 
Press to scroll up the list of options or to find a higher value
 
<DOWN> 
Press to scroll down the list of options or to find a lower value
 
<ENTER> 
Press to activate a menu option or a selected value
 
 
Menu Map 
Mode 
Programming Steps 
Description 
DMX Mode 
001–512 
Sets the DMX starting address 
Operation 
Modes 
SLAv (Son) 
Slave operating mode 
NASL (SLoU) 
Automatic mode, slow program 
NAFA (FASt) 
Automatic mode, fast program 
NStS (SrUn) 
Sound-Active mode 
Pan 
Normal Pan 
PAn 
Normal Pan operation 
Inverse Pan 
r PAn 
Inverse Pan operation 
Tilt 
Normal Tilt 
tiL 
Normal Tilt operation 
Inverse Tilt 
r tiL 
Inverse Tilt operation 
Display 
Normal 
Display 
diS 
Change the LCD display text position 
Inverse 
Display 
r diS 
Channel Mode 
13-Channel 
Mode 
13CH 
Selects the DMX personality 
8-Channel 
Mode 
8CH 
Manual Pan 
Range 
Pan 540 
PA54 
Select Pan angle range 
Pan 360 
PA36 
Pan 180 
PA18 
Manual Tilt 
Range 
Tilt 270 
Ti27 
Select Tilt angle range 
Tilt 180 
Ti18 
Tilt 90 
Ti 9 
Reset 
rESt 
Resets fixture 
Load 
LoAd 
Load factory defaults