Chauvet 250 Manuale Utente
Intimidator™ Spot LED 250 User Manual Rev. 11
Page 9 of 20
4.
O
PERATION
Control Panel
Operation
To access the control panel functions, use the four buttons located underneath the
display.
display.
Button
Function
<MODE/ESC>
Press to find an operation mode or to back out of the current menu
option
option
<UP>
Press to scroll up the list of options or to find a higher value
<DOWN>
Press to scroll down the list of options or to find a lower value
<ENTER>
Press to activate a menu option or a selected value
Menu Map
Mode
Programming Steps
Description
DMX Mode
001–512
Sets the DMX starting address
Operation
Modes
SLAv (Son)
Slave operating mode
NASL (SLoU)
Automatic mode, slow program
NAFA (FASt)
Automatic mode, fast program
NStS (SrUn)
Sound-Active mode
Pan
Normal Pan
PAn
Normal Pan operation
Inverse Pan
r PAn
Inverse Pan operation
Tilt
Normal Tilt
tiL
Normal Tilt operation
Inverse Tilt
r tiL
Inverse Tilt operation
Display
Normal
Display
diS
Change the LCD display text position
Inverse
Display
Display
r diS
Channel Mode
13-Channel
Mode
13CH
Selects the DMX personality
8-Channel
Mode
8CH
Manual Pan
Range
Pan 540
PA54
Select Pan angle range
Pan 360
PA36
Pan 180
PA18
Manual Tilt
Range
Tilt 270
Ti27
Select Tilt angle range
Tilt 180
Ti18
Tilt 90
Ti 9
Reset
rESt
Resets fixture
Load
LoAd
Load factory defaults