FAN/BLOWER KIT ASSEMBLY
Fan or blower kit is optional with this fireplace 
(circulating models only). Use of blowers or 
fans other than those manufactured by DESA 
Heating, LLC voids warranty. Fan is operated 
by  pressing  rocker  switch  (see  Figure  6)  in 
lower  right  hand  corner  of  fireplace  face. 
Blower  is  operated  by  turning  control  knob 
(not shown).
Fan/blower  kit  electrical  connections  are 
made  through  the  electrical  cover  plate  on 
side of fireplace a shown in Figure 6.
FIreplaCe InsTallaTIon
Continued
12 
1
/
4
" Ref.
6"
Ref.
12" Min.
9" Min.
1
1
/
2
" Max.
3" Nom.
33°
Combustible 
Material
Safe 
Zone for 
Projection of 
Combustible 
Materials
Fireplace Opening
Upper 
Section of 
Fireplace
Figure 4 - Mantel Clearances to 
Combustible Material (with Louver)
Wiring Instructions
1.  Remove electrical cover plate with bush-
ing  from  fireplace  by  removing  2  sheet 
metal screws as shown in Figure 6.
2.  Slide power source wiring through electri-
cal bushing opening and electrical cover 
plate  and  make  all  necessary  connec-
tions.
3.  Slide  all  wiring  connections  in  electrical 
housing as shown in Figure 6.
4.  Secure electrical cover plate with screws 
previously removed.
Note: Electrical housing and cover plate have 
sharp edges. Wear protective gloves.
MANTELS
A  mantel  may  be  installed  if  desired  (see 
Figures 4 and 5). Woodwork such as wood 
trims,  mantels  or  any  other  combustible 
material projecting from front face, must not 
be placed within 9" of fireplace opening and 
within 6" of top louver opening. Combustible 
materials above 9" and projecting more than 
1
/
2
" from fireplace must not be placed less 
than 12" from top opening of fireplace (NFPA 
STD 211, Sec. 7-3.3.3).
Figure 5 - Mantel Clearances to 
Combustible Material (without Louver)
12 
1
/
4
" Ref.
1
/
2
"
Max.
Upper Section
of Circulating
Fireplace
6"
Ref.
6"
Min.
33°
3" Nom.
*Note: Drawing
Not To Scale
Safe Zone For
Projection of
Combustible
Materials
Combustible
Material
12"
Min.
9"
Min.
Fireplace Opening
Top of 
Louvered
Opening
Electrical 
Bushing
Electrical 
Cover 
Plate
Rocker 
Switch
Figure 6 - Fan Switch-Electrical Bushing
Electrical 
Housing
Wire Nut (3x) 
(Not Supplied)
Outer Wrapper 
of Fireplace
Electrical Cover 
Plate and 
Electrical Bushing
Fireplace Chassis 
Ground
To Power 
Source
Receptacle 
(Supplied)
Power Source Wiring 
(Not Supplied)
Prewired Receptacle 
and Ground
Sheet 
Metal 
Screws