Desa VM36(B,H) Manuale Utente

Pagina di 32
www.desatech.com
108795-01V
18
6.  Repeat the process for the opposite door 
assembly.
7.  To adjust doors, slide them partially open. 
Using  a  screwdriver,  loosen  hold-down 
screws in the spring clip (see Figure 36) 
and pivot plate.
8.  Close both doors until evenly joined at the 
middle and note the gap at outer edges of 
face.
9.  Reopen one door at a time and retighten 
upper and lower hold-down screws.
10. Repeat process until both doors are even-
ly joined, spaced and working freely.
  CAUTION:  The  glass  pan-
els  become  very  hot  while  the
appliance  is  operating.  Do  not 
attempt  to  adjust  or  clean  the
glass doors until the appliance 
has fully cooled. 
The doors may be removed for replacement 
or cleaning as follows:
1.  Partially open door and press up on upper 
spring clip with a screw driver until outer 
top pivot pin is free of clip.
2.  Fully fold frame assembly and slide upper 
edge  towards  center  of  firebox  opening 
until guide pins are free of frame rail (see 
Figure 37).
 CAUTION:  Always  operate
the appliance with the doors ei-
ther fully opened or fully closed. 
Operating  the  appliance  with
the doors partially open can re-
sult in improper venting of flue
products.
INstallatIoN
Continued
Figure 36 - Adjusting Glass Doors
Spring 
Clip
Hold-Down 
Screw
Side 
Front 
Face
Partially 
Opened 
Door
Figure 37 - Removing Glass Doors
Spring Clip
Press 
Spring Clip 
to Release 
Pivot Pin
Remove Bottom Pin From 
Pivot Plate While Sliding Door 
Out of the Upper Track
Pivot Plate
Fold Bi-Fold 
Door After 
Releasing 
Spring Clip 
and Slide 
Door Out of 
Upper Track
OPENING VENT DAMPER
Vent damper must be locked in the full open 
position  before  operating  fireplace.  If  vent 
damper is not open, fireplace will not light.
CLOSE
OPEN
VENT DAMPER MUST BE LOCKED
IN THE FULL OPEN POSITION
TO OPERATE THE APPLIANCE
Figure 38 - Opening Vent Damper