INSTALLATION
Continued 
4.. Place. log. set. assembly. in. center. of.
fireplace. floor.. Make. sure. front. faces.
forward.
5.. Install.gas.connector.tube.into.gas.supply.
fitting. Carefully shape tube to attach to 
adapter fitting being careful not to kink 
tube.
6.. Install. provided. gas. connector. tube.
into the gas inlet fitting (see Figure 7, 
page 8).
7.  Test for leaks following instructions under 
Testing Burner for Leaks.
Repositioning Gas Inlet to Left Side of 
Unit
1.  Remove venturi and gasket by unscrew-
ing  two  screws  under  chassis  (see 
Figure 8).
2.  Unthread  elbow  fitting  from  orifice  (see 
Figure 8).
3.  Remove orifice and brackets by unscrew-
ing two screws on right side of unit (see 
Figure 8).
4.  Install orifice and brackets into left side of 
unit using screws removed in step 1.
5.. Install. venturi. and. gasket. under. bottom.
burner and into repositioned orifice and 
brackets (see Figure 8).
6.  Thread elbow fitting back into orifice. Ap-
ply thread sealant to orifice threads (see 
Figure 8).
7.. Install. gas. connector. tube. that. comes.
with  log  set  into  gas  inlet  fitting  (see 
Figure 8).
8.  Install supplied brass adapter fitting that 
comes  with  log  set  into  fireplace  gas 
supply. pipe.. Use. thread. sealant. (see.
Figure 8).
9.. Place. log. set. assembly. in. center. of.
fireplace. floor.. Make. sure. front. faces.
forward.
10..Install.gas.connector.tube.into.gas.supply.
fitting. Carefully shape tube to attach to 
adapter  fitting.  Be  careful  not  to  cause 
kinks.in.tube.
11. Test for leaks following instructions under 
Testing Burner for Leaks.
TESTING BURNER FOR LEAKS
1.. Generously.apply.noncorrosive.leak.de-
tection fluid to all connections.
 WARNING: Never check for 
gas leaks with open flame.
2.  Light  burner  with  shutoff valve  no more 
than. half. open. and. holding. a. match.
slightly.in.front.of.the.pan.(see.Lighting 
Instruction
s, page 10).
3.  Inspect all connections for bubbles, raw 
gas odors, or flame from any area other 
than  burner.  If  leaks  are  detected,  shut 
off. gas. valve. immediately.. Tighten. or.
reassemble.the.loose.connections.using.
pipe joint compound until burner system 
is.leak.free.
4.  When  finished  testing,  turn  gas  shutoff 
valve OFF to extinguish all flames.
Figure 8 - Repositioning Gas Inlet to Left 
Side of Unit