RECOMMENDED RAID CONFIGURATIONS 
 
 
RAID 
level 
RAID Array 
size 
Segment 
size 
Disk type 
Journal 
1 or 10 
As required 
256 
FC or SAS recommended 
Meta Data 
1 or 10 
As required 
256 
FC or SAS recommended 
  Journal and Meta Data may reside in separate 
LUN‟s carved from the same RAID Array if 
required in small implementations. 
However, the ideal condition is separate LUN‟s tied to 
separate RAID groups for Journal and Meta Data. If possible, these two LUN‟s should be 
on a different storage system than the 
data LUN‟s.  
 
StorNext can stripe across multiple LUN‟s. It is recommended that multiple RAID 1 Groups 
be used for Journal and Meta data rather than similarly sized RAID 10
‟s. This allows 
multiple threads to be talking to disk offering enhanced performance. 
Data 
4+1 
256 
As required to meet performance 
criteria 
 
8+1 
128 
As required to meet performance 
criteria 
  Data 
– Based upon StorNext file system header block size of 1MB, it is important to keep 
this in mind when selecting the segment size. RAID Array (also called Group) size and 
appropriate segment size should result in stripe size of 1MB.  This will result in  optimizing 
write throughput speeds. Ex. RAID5 4+1 (4 data) drives x 256K (seg size) = 1 MB Write 
stripe & RAID5 8+1x128K (seg size) = 1 MB stripe.  
  Note 
– this rule does not apply to all deployments and could be dramatically different for 
oil and gas industry deployments among others. It is very important to understand the I/O 
block size of the applications sitting atop the StorNext File system. 
Data 
4+2 
256 
As required to meet performance 
criteria 
 
8+2 
128 
As required to meet performance 
criteria 
•  Some customer applications may specify SATA drives and/or require additional RAID 
protection. The DS3000/DS4700/DS5000 storage servers offer additional levels of RAID 