FMI V36SH Manuale Utente

Pagina di 24
www.fmiproducts.com
108662-01L
11
55 
5
/
8
"
39 
3
/
8
"
34 
1
/
2
"
27 
3
/
4
"
0" CLEARANCE
0" CLEARANCE
*10 
1
/
2
"
*10 
1
/
2
"
* These dimensions allow for min. Clearances to 
a 45° projected side wall. However, clearances 
to projected mantel trims and facings are allowed 
within a min. Of 16" to a perpenducular wall as 
shown in figure 5, on page 10.
*14 
1
/
2
"
50 
3
/
8
"
71 
1
/
4
"
35 
5
/
8
"
41 
1
/
2
"
0" CLEARANCE
48"
82"
58"
*17"
41"
*17"
 
FOR 32" MODELS
FOR 36" MODELS
FOR 42" MODELS
INSTALLATION
Figure 6 - Minimum Mantel Clearances 
for Built-In Installation
Supplied
Firebox Hood
Must Be Used
at All Times
Wire-mesh
Screen
Firebox
Noncombustible
Material May
Project Off this
Surface above
the Firebox Hood
Mantel Shelf
Note: Any portion of the
mantel shelf must NOT
extend beyond this profile.
12" 16" 20"
1
/
2
"
3
/
4
"
12"
Note: All vertical
measurements are
from top of fireplace
hood opening to
bottom of mantel shelf.
These minimum
clearances replace any
other recommended
clearances supplied
with your ANSI Z21.11.2
approved gas logs.
Wall board or facing
material (above
firebox) may be of
combustible material,
including decorative
mantel ornaments or
other similar projec-
tions off of the facing
material.
Framing
Material
 
rough opening Dimensions for 
built-in Installation
Model
Front Width
(Inside to Inside)
Height
Depth
(Min.)
32"
34 
7
/
8
"
36 
3
/
4
"
16 
1
/
4
"
36"
41 
1
/
2
"
40 
1
/
2
"
20 
3
/
4
"
42"
48 
5
/
8
"
44 
1
/
2
"
22 
5
/
8
"
table 1
Depth
(Minimum)
Width
(Inside to Inside)
Height 
Figure 
7a
Figure 
7b
Figure 
7c
Figure 
7d
NotIce: If your installation does 
not  meet  the  minimum  clear-
ances shown, you must do one 
of the following:
•  raise the mantel to an accept-
able height
•  remove the mantel
buIlt-IN FIRebox INstAllAtIoN
Built-in  installation  of  this  firebox  involves 
installing firebox into a framed-in enclosure. 
This makes the front of firebox flush with wall. 
Optional brass trim accessories are available 
(see Accessories, page 18). The brass trim 
will extend past sides of firebox approximately 
1/2". This will cover the rough edges of the 
wall opening. If installing a mantel above the 
firebox, you must follow the clearances shown 
in Figure 6. Follow the instructions below to 
install the firebox in this manner.
1.  Frame in rough opening. The firebox fram-
ing should be constructed of 2 x 4 lumber 
or  heavier.  Use  dimensions  in  Table  1 
and  rough  opening  layout  in  Figure  7a. 
Adjust  framing  so  that  firebox  flushes 
with finished wall surface. If installing in 
a corner, use dimensions in Figures 7b, 
7c and 7d for rough opening.
2.  Install gas piping to firebox location. See In-
stalling Gas Line, page 12 and Connecting 
to Gas Supply 
in log set owner’s manual.