Garmin gps 92 Manuale Utente

Pagina di 6
Panel mount GPS’s 
 
Garmin 155XL/250XL/300XL 
Garmin 155XL/250XL/300XL connections to TruTrak autopilot 
J1 on 
Garmin unit 
Signal Name 
(Garmin) 
Signal Name 
(TruTrak) 
P101 on 
TruTrak DII/ADI/ 
Sorcerer 
19 or 
GPS RS 232 OUT 2 
Primary Serial Input 
17 / 25 
24 
GPS RS 232 OUT 1 
Primary Serial Input 
17 / 25 
16 
GPS ARINC 429 OUT A 
ARINC-A 
14 / 26 
15 
GPS ARINC 429 OUT B 
ARINC-B 
15 / 27 
If you use pin 19 then you do not need to enter the setup mode as described below to select output type. 
This output also has a selectable Baud rate.  See pilots guide   
Remove the data cards turn the unit on. Press “enter” in response to “Select operating mode Normal?”  Press “enter” in 
response to “No Jeppesen database rte / prx limited to user wpts ok?”  After the satellite status page is displayed for 5 seconds 
the unit may be turned off. 
With power OFF press and hold the ENT key and turn the power on (release the ENT key when the display activates).  You 
should be in the TEST MODE.  Rotate the outer knob to advance to I/O Channel 1. Press the CRSR key then rotate the outer 
knob to Select Output rotate inner knob to select “Aviation”.  Press the CRSR key then rotate the outer knob to Select ARINC 
429 CHANNEL.  Press the CRSR key then rotate the inner knob to advance to OUTPUT and select “w/o GAMA labels” 
Note that for the Garmin units, the autopilot will need to be set for 9600 baud. 
 
 
Garmin 430W and 530W 
 
Garmin 430 and 530 connections to TruTrak autopilot 
P4001 [P5001] on 
Garmin 430 [530] 
Signal Name 
(Garmin) 
Signal Name 
(TruTrak) 
P101 on 
TruTrak DII/ADI/ 
Sorcerer 
56 
GPS RS 232 OUT 1 
Primary Serial Input 
17 / 25 
46 
GPS ARINC 429 OUT A 
ARINC-A 
14 / 26 
47 
GPS ARINC 429 OUT B 
ARINC-B 
15 / 27 
 
Power 430/530 up and turn it on while holding down the ENT key. Release the ENT key when the display activates. After the 
data base pages, the first page displayed is the MAIN ARINC 429 CONFIG page. While in Configuration mode, pages can be 
selected by ensuring the cursor is off and rotating the small right knob. To change data on the displayed Configuration Page, 
press the small right knob (CRSR) to turn on the cursor. Turn the large right knob to change between data fields. Turn the large 
or small right knob to change a field that the cursor is on. Once you have made the desired selection, press the ENT key to 
accept the entry. 
With the MAIN ARINC 429 CONFIG page displayed, on the row labeled OUT, select SPEED Î Low  
and DATA Î429 GAMA.  In the VNAV row ENABLE LABELS. 
Advance to the MAIN RS232 CONFIG page. 
On the row labeled CHNL1, select OUTPUT Î Aviation. 
Note that for the Garmin units, the autopilot will need to be set for 9600 baud.