170PAX4 Maintenance Manual
57518L-001 Rev. A
3/18/05
Preventive and Corrective Maintenance
Corrective Maintenance—Power Fuse Replacement
Power Fuse Replacement
The print engine uses a metric-style fuse (5 × 20 mm IEC) rated for 5 Amps at 250 Volts that 
bears the certification mark of a known international safety organization (see 
). The power entry module comes with two approved fuses in the fuse holder: one is 
in-circuit and the other is a spare.
To replace a fuse, complete these steps:
1.
Turn off the print engine and unplug the power cord from the back of the 
print engine.
2.
Using a small-blade screwdriver, remove the fuse holder from the power entry module at 
the rear of the print engine.
3.
Carefully remove the fuse from the in-circuit location. 
4.
To remove the spare fuse, gently push the point of a pencil or the end of a paperclip 
through one of the two holes in the fuse holder. Repeat through the other hole.
5.
Insert the spare fuse in the in-circuit location. 
6.
Place a new fuse in the spare fuse location.
7.
Reinstall the fuse holder into the power entry module at the rear of the print engine.
8.
Reconnect the power cord and turn the print engine on.
The print engine should be ready for operation and the POWER light should be on. If 
power is not restored, an internal component failure may have occurred, and the print 
engine may require servicing. Se
.
Figure 61 • Installing a Fuse