Jacuzzi ProTech LCD Manuale Utente

Pagina di 56
US/Canada J-350/J-360/J-370 Models (60Hz)
240V/50A*
240V/60A**
240V/30A***
Voltage:
240 VAC
240 VAC
240 VAC
Number of Wires:
3
3
3
Frequency:
60Hz
60Hz
60Hz
Current Draw:
36A
43A
24A
Circuit Breaker:
50A, 2-Pole
60A, 2-Pole
30A, 2-Pole
Important Information:
*
In 50A configuration, the heater will not operate while both jets 
are running in high speed.  This is the factory setting.  Note: 
pump 2 runs only in high speed.
** In 60A configuration, the heater will operate while both jets pumps 
are running in high speed.  Note jets pump 2 runs only in high 
speed.
*** In 30A configuration, the heater will not operate while either jets 
pump is running in high speed.  Note: jets pump 2 runs only in high 
speed.
US/Canada J-380 Models (60Hz)
240V/60A*
240V/50A**
240V/40A***
Voltage:
240 VAC
240 VAC
240 VAC
Number of Wires:
3
3
3
Frequency:
60Hz
60Hz
60Hz
Current Draw:
46A
36A
31A
Circuit Breaker:
60A, 2-Pole
50A, 2-Pole
40A, 2-Pole
Important Information:
*
In 60A configuration, the heater will operate while any two jets 
pumps are running in high speed.  This is the factory setting.
** In 50A configuration, the heater will not operate while any two jets 
pumps are running in high speed.  Note: jet pumps 2&3 run only in 
high speed.
*** In 40A configuration, the heater will not operate while any jets 
pump is running in high speed.  Note: jet pumps 2&3 runs only in 
high speed.
5.0  Power Requirements
Jacuzzi Premium spas are designed to provide optimum performance and 
flexibility of use when connected to the maximum electrical service as listed
in the tables below.  If you prefer, your Jacuzzi Premium dealer can perform
a minor circuit board modification to allow the spa to accept different electri-
cal service. The operational considerations of these modifications are listed in
the footnotes below.
Page 7