Vulcan Materials cem20u ml-138078 Manuale Utente

Pagina di 28
— 7 —
ELECTRIC COMBI OVEN
7. Install tray support (if supplied) after oven
is installed onto stand. Use the four knurled
screws to secure the support to the legs.
FR
ONT
Figure 4: Assembled
Combination Oven Stand
LOCATION
Allow space for operating the oven. Do not
obstruct the ventilation port above the oven.
To provide ventilation access, allow 1" of
clearance on the left side of the oven and 2
1
/
2
"
clearance on the rear side of the oven. A
minimum of 18" must be provided on the right
side of the oven for operation, cleaning and
service. An optional heat shield assembly is
required if the clearance is less than 18" on
the right side of the oven.
LEVELING
Position the oven in its final installed location.
Place a level on the horizontal area of the
cabinet. Adjust the feet to level the oven in
both the left-to-right and front-to-rear
directions.
ELECTRICAL SPECIFICATIONS
The data plate is located on the front lower
right side of the oven.
Model
Voltage
Amperage
Kilowatts
Phase
CEM6U
208
26
9.4
3
CEM6U
240
25
10.3
3
CEM6U
480
11
9.4
3
CEM10U
208
43
15.5
3
CEM10U
240
40
16.8
3
CEM10U
480
19
15.5
3
CEM20U
208
54
19.5
3
CEM20U
240
48
24.0
3
CEM20U
480
27
22.1
3
Electrical Specifications Chart