eutech-instruments alpha ph differential probe Manuale Utente
Instruction
manuals
ECFP21A1A1
7
3.2.1. Pipe Tee Mounting
Eutech Instruments’ distinct body type for its 1½ inch differential pH sensor ensure optimal
positioning of the active pH sensor electrode in the process flow. Normally available pipe tees
positioning of the active pH sensor electrode in the process flow. Normally available pipe tees
vary widely in construction dimensions. CPVC pipe tees are most generally available with
schedule 80 walls. Stainless steel tees have thinner walls that change the final position of the
schedule 80 walls. Stainless steel tees have thinner walls that change the final position of the
sensor.
Common mounting arrangements are shown for the short nose pH sensors.
Recommended Tee Mounting Configurations
Figure 3.3: Short Nose Sensor Mounted
in Steel Tee or Schedule 40 PVC Tee
Optimal electrode placement with
minimum flow restriction
Dimensions: IN (mm)