calorique thermolar tank warming system Manuale Utente

Pagina di 12
INST
ALLA
TION
CCiirrccu
uiitt  O
Ovve
errccu
urrrre
en
ntt  P
Prro
otte
eccttiio
on
n
Fuse or circuit breaker rated for at least 120% of the system
amperage rating. 
FFa
au
ulltt  P
Prro
otte
eccttiio
on
n
The power supply must include a fault detector suitable for equip-
ment protection. This may be integral with the overcurrent protec-
tion.
INSTALLATION
CONTROL UNIT 
1.Determine the location of the control unit.
If the control unit will be positioned remotely from the tank, skip to the next section,
Heating Elements.
Attaching the control unit temporarily to the tank wall at this time will aid in aligning
the heating elements so that the power cords will reach the controller. 
Installing the control unit at eye level will make completion and operation easier.
2.Slide the strap through the slots provided on the back of the control unit.
 
3.Run the strap around the tank and slip the free end into the buckle.
4.Position the box about 4 feet/1.
2 m from the bottom of the tank and tighten the strap to hold it
in place.
Note
For best results, insulate underneath the tank. If the underside will not be accessible after
installation of the Thermolar system, then install insulation prior to final placement of the
tank. Insulating underneath the tank will help avoid excessive heat loss, reducing operat-
ing expense and the risk of damage to sensitive contents.
2