lift-master tcr2 Manuale Utente
Step 2 Setting Output Relay Mode
The TriCode
The TriCode
TM
receiver is factory set for momentary
relay output “MNT”.
(a) Momentary mode: The output relay will be on for
.5 seconds before turning off.
.5 seconds before turning off.
(b) Constant pressure mode: Output relay is
continuously on while receiving matching/valid ID
code from transmitter. The output relay will turn off
immediately once receiver does not receive a
matching/valid ID code from the transmitter (Refer to
figure 3).
continuously on while receiving matching/valid ID
code from transmitter. The output relay will turn off
immediately once receiver does not receive a
matching/valid ID code from the transmitter (Refer to
figure 3).
NOTE: If constant pressure mode is desired, open
front cover and move mode jumper from “MNT” to
“CST” (Refer to figure 2).
front cover and move mode jumper from “MNT” to
“CST” (Refer to figure 2).
FRONT VIEW
FIGURE 3
OUTPUT RELAYS & CONFIGURATION SWITCH SETTINGS
Step 3 Setting the Configuration Switch
The TriCode
The TriCode
TM
receiver is factory set for Linear/Delta-
3
TM
.
Locate the configuration switch and set it to the desired
RF mode of operation (Refer to figures 2 and 3). Modes
are as follows:
RF mode of operation (Refer to figures 2 and 3). Modes
are as follows:
Linear/Delta-3
TM
: works with all “Linear/Delta-3
TM
”
transmitters transmitted at 310 MHz using 8-bits ID
system.
system.
Multi
TM
: works with all “Multi-Code
TM
” transmitters
transmitted at 300 MHz using 10-bits ID system.
Stanley
TM
: works with all “Stanley
TM
radio” transmitters
transmitted at 310 MHz using 10-bits ID system..
FIGURE 2
3