efd 790 Guida All'Installazione

Pagina di 4
 M
 
VALVEMATE
 7090
M
 
Installation
1.
Connect the motor lead wire to
the I/0 connector position 7 (white
wire) and position 8 (brown wire).
2.
Install the barrel of red purge
compound (supplied) onto the
dispense valve-inlet fitting.
3.
Press the barrel into the fitting
while rotating one-half turn
clockwise. Do not overtighten.
4.
Attach the yellow end of the
barrel adapter assembly to the
barrel of red purge compound.
5.
Install the black quick-connect
into the air output connector
labeled "Constant Pressure.”
6.
Install a pink 20 gauge dispens-
ing tip (supplied, part #5120-1/4)
onto the valve outlet.
Prior to installing this valve, please
read the associated reservoir and
valve controller operating instruc-
tions to become familiar with the
operation of all components of the
dispensing system.
1
4
5
2
3
6