ge-interlogix simon 3 Manuale Utente

Pagina di 68
Simon Security System
36
Option 60: Secure Arming (Default = off)
Determines whether an access code is required when arming the system (on) or not 
(off).
This option does not affect keychain touchpad arm/disarm operation.
¾
To turn on Secure Arming, press:
Add—Option #—60—DONE.
¾
To turn off Secure Arming, press:
Delete—Option #—60—DONE.
Option 61: Demo Mode (Default = off)
Determines whether the panel operates as a demonstration model (on) or a standard 
panel (off).
Turning on this feature disables low battery supervision and allows the microphone to 
remain on continuously during an AVM session. System time setting is not required 
when this setting is on.
¾
To turn on Demo Mode, press:
Add—Option #—61—DONE.
¾
To turn off Demo Mode, press:
Delete—Option #—61—DONE.
Option 62: Supervisory Protest (Default = off)
Determines whether the panel protests arming if it has not received a supervisory sig-
nal from any sensor 15 minutes before arming (on) or not (off).
Note  
This feature must be turned 
on for European installa-
tions, but turned off for U.S. 
installations.
¾
To turn on Supervisory Protest, press:
Add—Option #—62—DONE.
¾
To turn off Supervisory Protest, press:
Delete—Option #—62—DONE.
Option 63: 24 Hour Time (Default = off)
Determines whether the panel uses a 24-hour clock (on) or 12-hour clock (off).
¾
To turn on 24 Hour Time, press:
Add—Option #—63—DONE.
¾
To turn off 24 Hour Time, press:
Delete—Option #—63—DONE.
Option 64: No Arm on Panel Low Battery (Default = off)
Determines whether the system prevents users from arming if a low CPU battery con-
dition exists (on) or not (off).
¾
To turn on No Arm on Panel Low Battery, press:
Add—Option #—64—DONE.
¾
To turn off No Arm on Panel Low Battery, press:
Delete—Option #—64—DONE.