Belden 1594A 008U1000 Copper Cable - 1000FT Guida Specifiche

Pagina di 3
CEC/C(UL) Specification:
CMR
EU Directive 2011/65/EU (ROHS II):
Yes
IEEE Specification:
POE per IEEE 802.3af & POE+ per IEEE 802.3at-2009
EU CE Mark:
Yes
EU Directive 2000/53/EC (ELV):
Yes
EU Directive 2002/95/EC (RoHS):
Yes
EU RoHS Compliance Date (mm/dd/yyyy):
01/01/2004
EU Directive 2002/96/EC (WEEE):
Yes
EU Directive 2003/11/EC (BFR):
Yes
CA Prop 65 (CJ for Wire & Cable):
Yes
MII Order #39 (China RoHS):
Yes
Telecommunications Standards:
Category 5e - TIA 568.C.2
ANSI Specification:
ANSI/TIA 568-C.2 Category 5e and ANSI/ICEA S-90-661-2012 Category 5e
Other Specification:
ANSI/ICEA S-56-434 Outdoor Use, ANSI/ICEA S-100-685 Indoor/Outdoor Use and ANSI/ICEA S-99-689
Broadband Outdoor Use
Flame Test
UL Flame Test:
UL1666 Vertical Riser
Suitability
Suitability - Indoor:
Yes
Suitability - Outdoor:
Yes
Suitability - Aerial:
Yes - When supported by messenger wire
Suitability - Burial:
No
Sunlight Resistance:
Yes
Plenum/Non-Plenum
Plenum (Y/N):
No
Plenum Number:
1585A
Non-Plenum Number:
1583A
Electrical Characteristics (Overall)
Nom. Mutual Capacitance:
Capacitance (pF/ft)
15
Maximum Capacitance Unbalance (pF/100 m):
330
Nominal Velocity of Propagation:
VP (%)
68
Maximum Delay:
Delay (ns/100 m)
510 @ 100MHz
Max. Delay Skew:
Delay Skew (ns/100 m)
45
Maximum Conductor DC Resistance:
DCR @ 20°C (Ohm/100 m)
9.38
Max. Operating Voltage - UL:
Voltage
300 V RMS
Maximum DCR Unbalanced:
DCR Unbalance @ 20°C (%)
3
Electrical Characteristics-Premise (Overall)
Premise Cable Electrical Table 1:
Freq. (MHz) Max. Attenuation (dB/100 m) Min. NEXT (dB) Min. PSNEXT (dB) Min. ACR (dB) Min. PSACR (dB) Min RL (dB) Min. SRL (dB)
1
2.000
65.3
62.3
63.3
60.3
20.000
23
 
Page 2 of 3 
08-16-2017
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1594A  Multi-Conductor - Category 5e Indoor/Outdoor CMR/CMX Cable