Belden 10GX62F 0061000 Copper Cable - 1000FT Guida Specifiche

Pagina di 4
Bulk Cable Weight:
38 lbs/1000 ft.
Max. Recommended Pulling Tension:
45 lbs.
Min. Bend Radius/Minor Axis:
1.200 in.
Min. Bend/Installation:
3 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CMR
CEC/C(UL) Specification:
CMR
EU Directive 2011/65/EU (ROHS II):
Yes
EU CE Mark:
Yes
EU Directive 2000/53/EC (ELV):
Yes
EU Directive 2002/95/EC (RoHS):
Yes
EU RoHS Compliance Date (mm/dd/yyyy):
03/07/2011
EU Directive 2002/96/EC (WEEE):
Yes
EU Directive 2003/11/EC (BFR):
Yes
CA Prop 65 (CJ for Wire & Cable):
Yes
MII Order #39 (China RoHS):
Yes
Telecommunications Standards:
Category 6A - TIA 568.C.2
ANSI Specification:
ANSI/TIA 568-C.2 Category 6A
Applicable Patents:
Country
www.belden.com/p
Flame Test
UL Flame Test:
UL1666 Riser
C(UL) Flame Test:
FT4
CSA Flame Test:
FT4
Suitability
Suitability - Indoor:
Yes
Suitability - Outdoor:
No
Suitability - Burial:
No
Sunlight Resistance:
No
Non-halogenated:
No
Plenum/Non-Plenum
Plenum (Y/N):
No
Plenum Number:
10GX63F
Electrical Characteristics (Overall)
Nom. Mutual Capacitance:
Capacitance (pF/ft)
17.000
Maximum Capacitance Unbalance (pF/100 m):
90
Nominal Velocity of Propagation:
VP (%)
64.000
Maximum Delay:
Delay (ns/100 m)
538 @ 100MHz
Max. Delay Skew:
Delay Skew (ns/100 m)
45.000
Maximum Conductor DC Resistance:
DCR @ 20°C (Ohm/100 m)
8.200
Max. Operating Voltage - UL:
 
Page 2 of 4 
09-16-2016
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
10GX62F  Multi-Conductor - Enhanced Category 6A F/UTP Bonded-Pair Cable