General Description:
CAT6A (500 MHz), 4 Pair, U/UTP-Unshielded, Outdoor OSP, Premise Horizontal Cable, 23 AWG Solid
Bare Copper Conductors, Polyolefin Insulation, Patented X-Spline, Gel-Filled, Polyolefin Inner Jacket,
EquiBlock™ Technology, Ripcord, UV-Resistant LLDPE Jacket
Usage (Overall)
Suitable Applications:
Outside Plant, 10 Gigabit Ethernet, Wireless, Wi-Fi, 100Base TX, 100Base VG ANYLAN, 155ATM,
622ATM, HDBASET, 4K, NTSC/PAL Component or Composite Video, AES/EBU Digital Audio AES51,
RS-422, PoE, PoE Plus
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
4
23
Solid
BC - Bare Copper
Total Number of Conductors:
8
Insulation
Insulation Material:
Insulation Material
PO - Polyolefin
Separator
Separator Material:
Patented X-spline Central Member
Inner Shield
Inner Shield Material:
Inner Shield Trade Name
Type
Inner Shield Material
Coverage (%) Dia. (in.)
Patent Pending EquiBlock Barrier Tape Tri-Laminate Polyester / Foil / Polyester 100.000
0.260
Inner Jacket
Inner Jacket Material:
Layer # Inner Jacket Material Nom Wall (in.) Nom. Dia. (in.)
1
Black LLDPE
0.020
0.260
Inner Jacket Ripcord:
No
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Black PO - Polyolefin
Outer Jacket Diameter:
Nom. Dia. (in.)
0.355
Outer Jacket Ripcord:
Yes
Pair
Pair Color Code Chart:
Number Color
1
White/Blue
2
White/Orange
3
White/Green
4
White/Brown
Mechanical Characteristics (Overall)
Storage Temperature Range:
-40°C To +75°C
Installation Temperature Range:
-40°C To +60°C
Operating Temperature Range:
-40°C To +75°C
Non-UL Temperature Rating:
75C
 
Page 1 of 4 
08-29-2017
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
OSP6AU  Multi-Conductor - Category 6A Outside Plant Cable