Belden 7960A 1SW1000 CAT 5e Cable Guida Specifiche
3
Belden PROFINET Selling Points
Why do we utilize a quad design?
The cable’s quad design gives it a smaller
diameter than other paired, 22 AWG PROFINET
cables, making it more pliable while remaining
compatible and easy to install with Siemens
Fast Connect, Lumberg Automation connectors
or Belden metal body plugs.
diameter than other paired, 22 AWG PROFINET
cables, making it more pliable while remaining
compatible and easy to install with Siemens
Fast Connect, Lumberg Automation connectors
or Belden metal body plugs.
What is the advantage of the UL-PLTC
rating on all three products?
rating on all three products?
•
The PLTC rating specifically allows the
cables to be run in existing cable trays
with other power-limited cables, with no
separate routing needed.
cables to be run in existing cable trays
with other power-limited cables, with no
separate routing needed.
•
With these ratings, network engineers can
better insure their networks against hazards
and harsh conditions, reducing risk and
maximizing both network efficiency and
reliability for mission-critical applications.
better insure their networks against hazards
and harsh conditions, reducing risk and
maximizing both network efficiency and
reliability for mission-critical applications.
74011E
74011NH
74011PU
74011NH
74011PU
74010E
74010NH
74010PU
74010NH
74010PU
PROFINET Cat6A – 10 Gb/s
•
74010E
74010NH
74010PU
74011E
74011NH
74011PU
Product Type
Type A
Type B
Conductor
•
Solid 22 AWG
•
Bare copper
•
Solid conductor
•
Stationary applications
•
Stranded 23 AWG 7 x 0.22 mm
•
Bare copper
•
Flexing – can be installed in panels or plant floors
Shielding
Foil/Braid >85%
Foil/Braid >85%
Jacket Type
PVC
LSNH
PUR
Halogen free
PVC
LSNH
PUR
Halogen free
UL Design
AWM 20726
AWM 20851
AWM 21292
AWM 20726
AWM 20851
AWM 21292
CMX Outdoor
Rated
-
-
-
-
-
-
Sunlight
Resistant
-
✔
✔
-
✔
✔
Operating
Temperature
-40 °C to +80 °C
-40 °C to +80 °C
Oil Resistant
•
IEC 60811:404
•
IEC 60811:404
Flame
Ratings
•
Vertical flame test:
IEC 60332-1-2
•
Vertical flame test:
IEC 60332-1-2
•
Horizontal flame test:
CSA FT2
•
Vertical flame test:
IEC 60332-1-2
•
Vertical flame test:
IEC 60332-1-2
•
Horizontal flame test:
CSA FT2
•
NEC type PLTC listed, which is approved for cable tray use in Class I Div II hazardous areas
•
NEC type ITC per article 727 – ITC cables may carry up to 5 amps at 150 V, which is significantly greater than that allowed by PLTC
•
600 V AWM-rated for wiring equipment, such as motor control centers and switchgear