INPUT ZONES
Number of Zones: 400 - 4, 800 - 8
Zone Connector: terminal block
Zone Types:
 N.O./N.C. contact,  
 2.8K Thermistor -20° to 150ºF  |  -30º to 65ºC 
Zone Characteristics: 5.11K to 2.85V (Short cir-
cuit current: 1mA max.)
A/D Converter Resolution: 10 bits ±2 LSB
Zone Protection: 5.5VDC Metal Oxide Varistor 
with fast acting diode clamps.
RELAY OUTPUT
Rated for 1A 30VAC/1A 30VDC maximum.
LED INDICATORS
System On, Phone In Use, Alarm, Battery Ok. 
MICROPHONE
Internal Electret Condenser: For listening in 
to on-site sounds and detecting high sound levels.
PHONE INTERFACE
Line RJ11 Jack: For connection to a two-wire 
analog telephone line. (6’ modular cord included)
Extension RJ11 Jack w/ Line Seizure: For 
connecting other devices on the same telephone 
line, devices connected to this jack are discon-
nected in the event that the 400 must dial out for 
an alarm. 
Phone Line Protection: Metal Oxide Varistor & 
self-resetting fuse
POWER SUPPLY
Power Supply: 120VAC/9VDC 60Hz 6W wall 
plug-in transformer w/6’ cord.
Power Consumption: 1.5 Watts
Power Protection: Metal Oxide Varistor
Battery Backup: Six size-C alkaline batteries 
(not included), providing up to 24 hours of back-
up time.
ENVIRONMENTAL
Operating Temperature:  
32° to 122°F  |  0° to 50°C
Operating Humidity:  
0–90% RH non-condensing
Storage Temperature:  
32° to 140°F  |  0° to 60°C
PHYSICAL
Dimensions: 2.1 x 7.8 x 8.8”d  | 5 x 20 x 22mm 
Weight: 8 lbs.  |  3.6kg
Enclosure: Indoor rated plastic housing suitable 
for wall or desktop installation 
Technical Specifications 