Sony E 10-18 mm f/ 4 OSS Lens Manuale
![Sony](https://files.manualsbrain.com/attachments/7e61ba04cadfce70cb41a1a70ef1d62a30f0a5fe/common/fit/150/50/682a2570dc00831b079177f57c62a2915dd3423eb752334060fbcf750d89/brand_logo.png)
4-42
SAL16105 (DT 3.5-5.6/16-105) (DT 16-105mm F3.5-5.6)
9)
When the infinity position check finishes normally, the message “ Move Focus to Near position at about 5sec. ” is displayed on the
pop-up window.
Set the focus to near position, press down the ENTER key.
Fig.4-12-9
10) When the near position check finishes normally, the message “ Reverse Focus to infinity position at about 5sec. ” is displayed on the
pop-up window.
Set the focus to infinity position, press down the ENTER key.
Fig.4-12-10
11) When the ROM Data Inspection finishes normally, the message “ Select dSB. Then push [ENTER]. ”
Being based on the focus shift amount calculated by “ 4-7. FOCUS-SHIFT CHECK/ADJUSTMENT (APERTURE (AMOUNTOF
SPHERICAL ABERRATION)) ”, select the button and perform the Write dSB.
Fig.4-12-11
Fig.4-12-12
12) When the Write dSB finishes normally, “ OK ” appears on the pop-up window.
Fig.4-12-13