Sony E 10-18 mm f/ 4 OSS Lens Guida Specifiche

Pagina di 80
4-34
SAL135F28 (STF 2.8(T4.5)/135) (135mm F2.8 [T4.5] STF)
4-6-2. Focus Pattern Check (Focus Pattern)
Equipment
• Personal Computer
• Finished Inspection JIG (AC 100 V only)
• Lens Adjustment Program (ActuatorChecker)
1. Preparations
1)
Connected to equipment with checking lens. (Refer to Section 4-1-3.)
2)
Start up of “ActuatorChecker.exe”.
3)
Click 
[Set up]
, and perform the initial setting. (Refer to Section 4-1-4.)
2. Checking Method
1)
Click the 
[Focus Pattern]
.
Fig.4-6-2
2)
The Serial window appears. Input the lens serial number.
Note:
When 
[OK]
 is clicked without inputting the serial number, the date executed is displayed on the completion window of each
item.
Fig.4-6-3
3)
The message “Move FOCUS to Infinity position. Then push [ENTER].” is displayed on the pop-up window.
Set the focus to the Infinity position and press down the ENTER key.
Fig.4-6-4