viii. Reference Information
Complete Command Reference
load [default] 
Load the settings stored in Flash and use 
them as the current or working settings. If 
default
 is specified as well, factory 
settings will be loaded. Use this after power 
failure to restore settings saved in Flash.
netstat 
Display current network status, including 
TCP packet statistics and the current state of 
each TCP and UDP socket in the system.
ping [-s] hostIPaddress 
[datasize [packetnumber]]
"
ping
" another TCP/IP host, specified by 
hostIPaddress, on the network. datasize is 
the datagram packet size which defaults to 
64 bytes if no size is included in the syntax 
and packetnumber is the number of requests 
to be sent.
To use a host or IP name instead of the 
address, you must have set the DNS server 
on the Q53. Use the command "
set 
sysinfo dns...
" to do this.
For example:
ping 192.168.11.30
quit
Close the telnet command session.
restart
Perform a warm boot or hardware reset 
simulating a power-on reset. This will 
restore current settings to those stored in 
Flash as the Flash settings will be read and 
loaded into memory upon bootup.
save [default]
Save the current settings to Flash so they are 
remembered after power cycles. Sysinfo, 
snmp, user, and sntp settings will be saved. 
If 
default
 is specified as well, factory 
settings will be saved to Flash overwriting 
any new settings you have configured. 
Resetting the unit is not required.
Table 7—Miscellaneous Commands
Command Syntax
Description