NINGBO DOOYA MECHANIC & ELECTRONIC TECHNOLOGY CO. LTD. DD6010 Manuale Utente

Pagina di 3
Tubular Motor-
DM18LE/S
Specification
(A-OO)
Rated Voltage(V)
Rated Torque(N.m)
Functional features
Jogging&tilt function
Set electronic limit
Set /delete the third limit position
Low standby power 
Integrated radio control
Setting up+add emitter+delete emitter
Motor direction setting option
Resistance stop function
-10
85
Emission frequency(MHz)
Rated speed(RPM)
1.  
Please charge the battery and make sure it is fully charged before the first use
2.
 Don’t operate motors wheuin low wltage alarm:
   ①
Motor stop running When the supply voltage is lower than 7 v, and it will restart
   again when the voltage is greater than 7.5V
   ②
If the voltage is less than 10v, the motor will alarm for 10 times to prompt it needs
   to be charged every timewhen the motor is working.
3.  
Optrating:
   ①
The valid interval of the emitter button is 10s,the emitter will quit the set after 10s
   ②
The motor will run or beep for hint,please do the next step after the hint.
4. 
Set limit position:
   ①
After the up limit and down limit setting,and the up limit down limit and third limit   
   position are at the same location
   ②
After limit setting,with power and memory function;  
   ③
Into the match-code status 2 minutes later, it will quit out the setting limits status 
   automatically 
   ④
It will delete every memory and restore the factory settings
5.  
When the motor running without any operation, the maximum running time is 6
   minutes,it will stop automatically
6. 
 If the emitterlost,please set up again with new emitter
&
The motor has a built-in battery,using the charger to 
recharge.You can also use solar panels to charge;when 
the battery is low, insert thecharge,charger light shows 
red light.batteries isfull when the red light turns to green.
Note:When the battery power is low,you can hear the alarm ten "beep"  every time the 
motor  runs. It indicates the battery needs to be charged. Then plug in the charger with 
red light.The light turns green when the battery is fully charged.
Operating 
temperature
Parameter
Type
Rechargeable Description
 
Signal wire
DM18LE/S
0.2N.m
12V
433.925MHz
80RPM