Connector Pinout 
On module side a Samtec HW-04-15-F-D-325-SM connector with the following pinout is used: 
1: 
/Enable  
Enable/Disable RF-part. Connect to 0V for normal operation 
2: 
+3.3V 
Power Supply. Connect to +3.3V (3.15V .. 6.0V) 
3: 
GND 
Ground connection. Connect to 0V 
4: 
Q Out 
Analog Output Q-Channel 
5: 
I Out 
Analog Output I-Channel 
6: 
VCO 
Frequency control input. A voltage between 1..5V adjusts 
TX Frequency by 0 .. 50MHz. Can be used for FSK or FMCW 
7: 
S&H 
Sample&Hold Switch Analog Output. Leave it open or connect 
to +3.3V for normal operation 
8: 
Temp 
Temperature Sensor output of LMT84 temperature sensor 
Mechanical Drawing 
FCC Labelling Information: (label to be placed into the recess position * shown in the 
mechanical drawing above 
FCC ID: WH3 -MC-133 
AGD-T7813-125 (MC-133)
Frequency 24.125GHz
Issue 1
Serial No:   in barcode or datamatrix format
 
*
Datasheet 
AGD-T7813-125  
Issue ‘1’
 MC-133