Connector Pinout
On module side a Samtec HW-04-15-F-D-325-SM connector with the following pinout is used:
1:
/Enable
Enable/Disable RF-part. Connect to 0V for normal operation
2:
+3.3V
Power Supply. Connect to +3.3V (3.15V .. 6.0V)
3:
GND
Ground connection. Connect to 0V
4:
Q Out
Analog Output Q-Channel
5:
I Out
Analog Output I-Channel
6:
VCO
Frequency control input. A voltage between 1..5V adjusts
TX Frequency by 0 .. 50MHz. Can be used for FSK or FMCW
TX Frequency by 0 .. 50MHz. Can be used for FSK or FMCW
7:
S&H
Sample&Hold Switch Analog Output. Leave it open or connect
to +3.3V for normal operation
to +3.3V for normal operation
8:
Temp
Temperature Sensor output of LMT84 temperature sensor
Mechanical Drawing
FCC Labelling Information: (label to be placed into the recess position * shown in the
mechanical drawing above
FCC ID: WH3 -MC-133
AGD-T7813-125 (MC-133)
Frequency 24.125GHz
Issue 1
Serial No: in barcode or datamatrix format
*