4. Commissioning
 
Page 20 
 
MF0150A2A.doc                             Manual for ION-M7P/85P/17EP/19P 
 
6. Notice: If any different or additional mounting material is used, ensure that the 
mounting remains as safe as the mounting designed by the manufacturer. The 
specifications for stationary use of the Remote Unit must not be exceeded. 
Ensure that the static and dynamic strengths are adequate for the environmental 
conditions of the site. The mounting itself must not vibrate, swing or move in any 
way that might cause damage to the Remote Unit. 
7. Notice: Observe all additional rules or restrictions regarding mounting that 
depend on the type of Remote Unit. For details refer to section 7.2.2 Mechanical 
Specification
. Install the unit vertically with the fan unit at the top. A maximum tilt 
angle of 25° from a vertical position must be kept, as in the following illustrations: 
 
8. Notice: 
A spacing of 50 mm (1.97 inch) around the unit is required. 
9. Notice: 
To ensure sufficient airflow when mounting the unit in enclosed spaces, 
two lid openings (one for the air inlet and the other for the air outlet) must be 
provided. Do not block these air inlets and outlets when mounting the Remote 
Unit. The size of each opening must equal at least 18 x 18 cm (> 300 cm
2
). 
Ensure that there is no thermal short circuit between the air inlet and air outlet. 
Make sure free airflow is not deflected or otherwise obstructed. 
 
Specified torques have to be observed for certain mounting procedures according to 
the following table: 
Type 
Tallow-drop 
screws 
Hex 
nuts 
Screw 
band lock
Spacing 
bolts 
PG 
(plastic) 
PG 
(alum.) 
Thread 
M 4 
M 8 
 
M 4 
M 8 
PG 13.5 
PG 29 
Specified 
torques 
3.3 N-m 
27 N-m
6 N-m 
2.3 N-m  27 N-m 3.75 N-m  10 N-m 
table 4-1 Specified torques