Installation 
 
 
EverGuard Express 
 
 
Installation 
2.1 
Power 
Power is supplied via by an external AC to DC transformer power source. Range: 
100~240 VAC, 50/60 Hz. 
 
The EverGuard Express connects to the wall via a Wall Mount attachment 
(provided) and into a power outlet via a power cable (provided). 
It requires a Lithium Polymer, ES700BAT_VF battery (provided) which provides 36 
hours backup power during temporary loss of power source. 
2.1.1 
Power Status 
A single LED provides the power status information. An Audible bad beep is 
sounded when disconnected. The table below details the power status indicators of 
the EverGuard Express control panel.  
 
 
Note: The EverGuard Express control panel emits bad beep when it is in 
AC fault. This is to remind you to make sure the power connection is 
reestablished. 
 
 
 
Power Status 
 
 
 
220V Connected 
Mains and battery OK 
 Green 
 
220V connected 
220V Disconnected 
One flash every 
second: battery OK, 
mains fault 
One flash every half 
second: battery low 
 Red Flashing 
Bad beep 
220V disconnected 
Table 1: Power Indicators
 
 
Note: After a configurable amount of time, all LEDs turn off to save 
battery life. The LEDs will turn ON every time a RF transmission occurs 
after which the panel will go to sleep mode again. 
2.2 
Inserting the Battery and SIM Card 
You must insert the SIM card and battery before mounting the EverGuard 
Express. The SIM card is placed underneath the battery. 
A Lithium Polymer, ES700BAT_VF battery is provided, which provides 36 hours