Essence Security International ltd. ES6502HCP Manuale Utente
PERS
Temp
2
1.1. Features
The EverGuard-Care™ Control Panel has the following features for ease of
operation:
operation:
The EMERGENCY and RESET buttons on the Control Panel are molded with Braille
characters for ease of recognition by visually impaired users
characters for ease of recognition by visually impaired users
A built-in high volume speaker plus a very sensitive microphone
Support for both half and full duplex conversation modes.
Visual indications (flashing lights), audible (beeps and sirens) and vocal (voice)
announcements are generated by the system alarms and statuses.
announcements are generated by the system alarms and statuses.
Within the premises, the Control Panel can communicate with up to 64 wireless
peripherals. Alarms triggered by these peripherals, as well as status reports, are sent from
the Control Panel to the Monitoring Station in accordance to the status of the peripheral.
peripherals. Alarms triggered by these peripherals, as well as status reports, are sent from
the Control Panel to the Monitoring Station in accordance to the status of the peripheral.
Certain environmental occurrences may trigger the
alarms:
Fire alarm triggered by the smoke detector,
Extreme temperature alarm – triggered by any of the peripherals
Opened door/window – triggered by the magnetic sensor
1.2. Monitoring Activities
Monitoring activity within the premises is also possible by specific features:
Activity Timer
Up to two programmable activity detection periods may be set for the Control Panel by
the Monitoring Station. These monitor activity within specific time slots during the day.
This feature may be enabled and disabled by the user.
the Monitoring Station. These monitor activity within specific time slots during the day.
This feature may be enabled and disabled by the user.
When enabled; a blue LED ring lights around the EMERGENCY button. If this function is
disabled this blue LED ring remains off.
disabled this blue LED ring remains off.
Fifteen (15) minutes prior to the end of the session, the Control Panel beeps and
displays a blinking blue LED ring. To stop this warning and reset the activity timer, press
the RESET button on the Control Panel. If during an activity period, you press the
emergency button on the Control Panel or on one of the emergency button peripherals
it generates an alarm. This action also resets the activity timer, but you should not use it
for this purpose, instead use the reset button on the Control Panel.
displays a blinking blue LED ring. To stop this warning and reset the activity timer, press
the RESET button on the Control Panel. If during an activity period, you press the
emergency button on the Control Panel or on one of the emergency button peripherals
it generates an alarm. This action also resets the activity timer, but you should not use it
for this purpose, instead use the reset button on the Control Panel.
If no activity was detected during the session, the Control Panel initiates an Inactivity