Essence Security International ltd. ES7000EG Manuale Utente
Operation
EverGuard Control Panel
51
Figure 20: Control Panel Screen
2. To edit a specific parameter, mark the relevant checkbox. The parameter is
then enabled and you can modify it.
3. Under Timer Delay, parameters enable you to set the, configure the
entry/exit timed devices using the following Timer Delay parameters:
Full Entry Timer
Full Exit Timer
Part Arm Entry Timer
Part Arm Exit Timer
The valid range for each of these parameters is 1 to 180 seconds.
For compliance with the EN 50131 standard, both Entry and Exit times must be
set to values of 45 seconds maximum.
set to values of 45 seconds maximum.
4. Under Sound, set the sound levels and functions of the alarm for the
following parameters:
Beep Level - The beep level controls the volume of the beep and can be
set from 1 to 7.
Internal Siren Sound Level – The internal siren sound level controls
the volume of the internal siren and can be set from 1 to 9, or it can be
set for Progressive (beginning at a lower decibel and escalates).
set for Progressive (beginning at a lower decibel and escalates).
Silent Panic – When Silent Panic is enabled, it is not necessary to set
the Beep level or the Internal Siren Sound level.
Internal Siren Duration – Determines the duration that the internal
siren sounds. The Internal Siren duration can be set between 5 to 180
seconds.
seconds.