Cisco 7513 AC PWR-7513-ACE= Manuale Utente

Codici prodotto
PWR-7513-ACE=
Pagina di 16
1200-Watt AC-Input Power Supply Replacement Instructions  13
Replacing a Power Supply
Figure 6
Supporting the Power Supply
Caution
To maintain agency compliance requirements and meet EMI emissions standards in a Cisco 7513
or Cisco 7576 chassis with a single power supply, the power supply blank must remain in the power supply
bay adjacent to the power supply. (See Figure 7.) Do not remove this blank from the chassis unless you need
to install a redundant power supply. To prevent system problems, do not mix AC-input and DC-input power
supplies in the same chassis.
Figure 7
Power Supply Blank
Replacing a Power Supply
To replace the power supply, follow these steps:
Step 1
Hold the power supply as shown in Figure 6 and slide it into the power supply bay. Push
the power supply all the way into the chassis until the sides are flush against the chassis
frame. To prevent damaging the backplane connector, do not force the power supply into
the bay.
Step 2
Use the large slotted screwdriver to tighten the captive screw that secures the power
supply to the chassis frame. (See Figure 5.)
Step 3
Reconnect the power cable to the power receptacle on the power supply.
Step 4
After the AC power cable is reconnected, reconnect the power cable at the power source
but do not turn on power to the new power supply.