IDEMIA Identity & Security France MPHAC001A Manuale Utente

Pagina di 74
 
Section 4 : Electrical Interface 
 
 
2015_2000007248-V1 - Draft 
This document and the information therein are the property of Morpho. They must not be 
copied or communicated to a third party without the prior written authorization of Morpho 
34 
June 2015 
 
 
Tamper Switch 
  
Figure 13: Tamper switch wiring 
Light Blue 
Switch 1 
 
Tamper switch contact 
Pink 
Switch 2 
 
Strip on tamper switch 
Operating principle for the switch 
 
Product installed on the wall plate: switch enabled (contact closed). 
 
Product opened (rear connectors accessible): switch disabled (contact open). 
Nominal characteristics of switch block 
Electrical  characteristics:  100  mA  at  30  VDC  max  (Resistive  load)  according  to  the 
safety extra low voltage standard. 
 
This MorphoAccess® SIGMA Lite Series terminal is part of security system; 
it  is  customer’s  responsibility  to  connect  the  tamper  switch  (contact)  to 
physical  access  controller,  in  order  to  detect  unauthorized  access  to  the 
connector blocks.