IDEMIA Identity & Security France MPHAC001A Manuale Utente

Pagina di 74
 
Section 4 : Electrical Interface 
 
 
2015_2000007248-V1 - Draft 
This document and the information therein are the property of Morpho. They must not be 
copied or communicated to a third party without the prior written authorization of Morpho 
43 
June 2015 
 
 
Ethernet connection 
Ethernet  interface  can  be  used  to  power  the  MorphoAccess®  SIGMA  Lite  Series 
terminal  through  POE  (Power  Over  Ethernet  -  IEEE802.3af  or  IEEE802.3at  type  1 
mode). According to the POE standard two modes are available: power on data pins 
and power on dedicated pins. 
Use  either  one  of  these  modes  depending  on  POE  implementation  on  your  local 
Ethernet network. 
 
Wi-Fi™ dongle must not be used with POE power supply. The POE doesn’t 
provide enough power for both the terminal and the Wi-Fi USB dongle. 
 
Ethernet cable shall be shielded 
Default Ethernet configuration 
By default, MorphoAccess® SIGMA Lite Series terminal is configured in DHCP mode 
Recommendations for RJ45 wiring 
Pin 
Signals 
Data  pair 
Data  pair 
Data  pair 
NC/POE pin 
dedicated (+) 
NC/POE pin 
dedicated (+) 
Data  
pair 2 
Ground/ pin 
dedicated (-) 
NC/POE pin 
dedicated (-) 
EIA / TIA 
T568B Colors 
White 
orange 
Orange 
White 
green 
Blue 
White blue 
Green  White brown 
Brown 
EIA / TIA 
T568A Colors 
White 
green 
White 
green 
White 
green 
White green 
White green 
White 
green 
White green 
White green 
Corel L120 
Colors 
Grey 
White 
Pink 
Orange 
Yellow 
Blue 
Purple 
Brown 
 
Figure 21: RJ45 wiring 
RJ45 plug pinout is compliant with 10/100 base T, IEEE802.3 Specification. Product is 
compliant also with MDI or MDI-X.