Section 7 : Recommendations 
 
 
2015_2000007248-V1 - Draft 
This document and the information therein are the property of Morpho. They must not be 
copied or communicated to a third party without the prior written authorization of Morpho 
57 
June 2015 
 
 
Notice 
The  manufacturer  cannot  be  held  responsible  in  case  of  non-compliance  with  the 
following recommendations or incorrect use of the terminal. 
General precautions 
 
Do not attempt to repair your terminal yourself. The manufacturer cannot be held 
responsible  for  any  damage/accident  that  may  result  from  attempts  to  repair 
components.  Any  work  carried  out  by  non-authorized  personnel  will  invalidate 
your warranty. 
 
Do not expose your terminal to extreme temperatures. 
 
Use  your  terminal  with  original  accessories.  Attempts  to  integrate  unapproved 
accessories to the terminal will void your warranty. 
 
Due  to  electrostatic  discharge,  and  depending  on  the  environment,  synthetic 
carpet should be avoided in areas where the terminal has been installed. 
Areas containing combustibles 
It is strongly recommended that you do not install your terminal in the vicinity of gas 
stations, petroleum processing facilities or any other facility containing flammable or 
combustible gasses or materials. 
Specific precautions for terminals equipped with a contactless 
smartcard reader 
It is recommended to install terminals equipped with a contactless smartcard reader 
at  a  certain  distance  (>  30cm)  from  metallic  elements  such  as  iron  fixations  or  lift 
gates or radio product (such as contactless smartcard reader). Performances in terms 
of  contactless  badge  reading  distance  will  decrease  when  metallic  elements  are 
closer. 
Ethernet connection 
It is recommended to use a category 5 shielding cable (120 Ohms). It is also strongly 
recommended to insert a repeater unit every 90m. 
Extreme  care  must  be  taken  while  connecting  Ethernet  wire  to  the  terminal  block 
board since low quality connection may strongly impact Ethernet signal sensibility. 
It is recommended to connect Rx+ and Rx- with the same twisted-pair wire (and to do 
the same with Tx+/Tx- and the other twisted-pair wire). 
Date / Time synchronization 
The terminal clock has a +/-10 ppm typical time deviation at +25°C (roughly  around 
+/-  6  sec  per  48  hours).  At  lower  and  higher  temperature  (but  within  normal