Shanghai Huace Navigation Technology LTD. A020012 Manuale Utente
6. Configuring the Receiver: Other Than Keypad and Display
P5E GNSS Reference Receiver User Guide
Page 38
In this screen, you can set all data logging parameters, and
determine whether the recording files will be affected by the FTP
Push. The parameters are mainly as follows:
➢ Auto Record: Select “Yes” or “No” to determine whether to log
data when the Master Log Switch is ON.
➢ Sample Interval: Select the observable rate from the dropdown
list.
➢ Store Location: Determine whether to store at internal storage
or external storage.
➢ Start Date: Set the start time of data log in UTC. Select “Yes” or
“No” option below to determine whether to start logging from
the set time.
➢ Duration Time: Set the time interval of recording.
➢ Storage: Set the storage limit of this thread.
➢ Circulating Memory: Select “Yes” or “No” to determine
➢ Storage: Set the storage limit of this thread.
➢ Circulating Memory: Select “Yes” or “No” to determine
whether to auto delete old files if the storage space is full.
➢ Storage Format: The default format of recording files is HCN.
➢ FTP Push: Decide whether to push the stored files to the FTP
➢ FTP Push: Decide whether to push the stored files to the FTP
server of your choice.
Click
to save the settings and back to the Log Settings
screen. Also, users can click
to abandon the changed
settings and back to Log Settings screen.
NOTE – to delete the record data, you can remove all the eight record
data by the total button clear all accounts. Also you can delete each
record data by clear button under the selected thread.