Shanghai Huace Navigation Technology LTD. A020012 Manuale Utente
P5E GNSS Reference Receiver User Guide
Page
57
7. D
EFAULT
S
ETTING AND
C
ONFIGURATION
F
ILES
Most of the receiver settings are stored in application files. The default
application file, Default.cfg, is stored permanently in the receiver, and
contains the factory default settings for the P5E GNSS reference receiver.
Whenever the receiver is reset to its factory defaults, the current settings
(stored in the current configuration file, copy.cfg) are reset to the values in
the default application file.
The P5E GNSS reference receiver extends the use of configuration files to
allow simplified receiver setting duplication in multiple receivers. This is
sometimes referred to as receiver cloning and is very useful when preparing
a large group of receivers for a field data collection campaign.
7.1. D
EFAULT RECEIVER SETTINGS
Function
Factory default values
SV Enable
All SVs enabled
General controls
Elevation mask
PDOP mask
0°
6
Lemo port
Baud rate
Format
Flow control
9600
8-None-1
None
DB9 port
Baud rate
Format
Flow control
9600
8-None-1
None
Log status
OFF
Differential data
OFF
Raw data
OFF
Ephemeris data
OFF
NMEA (GPGGA, GPGSV)
OFF
Reference position
Latitude
Longitude
Height
0°0’0.00000000’’
0°0’0.00000000’’
0.000
Antenna
Type
Measure Method
Height
None
2.0000 (Meter)
Antenna Phase Center
7.1.1. R
ESETTING THE RECEIVER TO FACTORY DEFAULTS
Log in the web page of the receiver tap and unfold the Receiver Reset
menu tap the Receiver Reset submenu click the [Confirm] button to
the right of Reset to Defaults field.