D.  Wiring The RF Wall Thermostat
TO PREVENT POSSIBLE DAMAGE TO THE EQUIPMENT OR PERSONAL
INJURY DUE TO ELECTRICAL SHOCK,  BE SURE THAT ALL
ELECTRICAL POWER TO THE THERMOSTAT HAS BEEN
DISCONNECTED BEFORE BEGINNING WIRING PROCEDURE.
1. Strip the power wires ends, 24 VAC (R) and the Common (C)
approximately 3/8 of an inch.
2. Use the Wire Reference Chart (Table 1) and connect the appropriate
conductor to the wire which protrudes from the back of the thermostat.
If this is a first time installation, note the thermostat wire color for future
reference in order to properly connect the thermostat wiring to the
ceiling assembly.
3. If the system has Heat Pump capability, strip and attach the Cool Active
or Heat Active Reversing Valve wire (O or B), according with the
system needs.
4. If a Gas Heat / Furnace system is to be operated from the thermostat,
strip and attach the Furnace system wire (W2).
5. If an Electric Heater system is to be operated from the thermostat, strip
and attach the Electric Heat wire (W1).
6. If the unit to be controlled by the thermostat has only one Fan speed,
connect both fan wires, Low Fan (G) and High Fan (GH), together.
7. Any unused wire should have its end insulated, using a wire nut or
crimp connector.
8. Gently push the excess thermostat wiring back into the wall opening.
Because the wall may have a different temperature inside when
compared to the outside, fill the wall opening with a noncombustible
insulation. Insure that wires cannot contact screws or sharp edges
     in the wall cavity.
9. Snap the thermostat body onto the base.
TABLE 1
E.  Selecting the Model for the RF Wall Thermostat
1. According with the system features that the RF Wall Thermostat is
going to control, a Model Number must be assigned during the power
up. See Table 2 for proper number.
2. When powering up the thermostat, hold the UP push button. Release the
button. The display will be blinking, showing the factory default Model
Number “15”.
3. Use the UP button to change that number for the proper number for
your installation (see Table 2).
4. After choosing the proper Model Number, wait about 6 seconds for the
unit to restart, saving your configuration.
5. If no action is taken for 6 seconds after powering up the thermostat, it
will restart without changing the Model Number.
TABLE 2
OPERATION INSTRUCTIONS
RF Wall Thermostat Buttons
Power
Press the POWER button to turn the system ON or OFF.
Up
Press the UP (
>) button to adjust setpoint up.
Down
Press the DOWN (
?) button to adjust setpoint down.
Mode
Press the MODE button to scroll through the modes:
FAN ONLY - COOL - DRY AIR - GAS HEAT - AUTO
CHANGEOVER and ELECTRIC HEAT
Fan Speed
Press the FAN button to scroll through the fan speeds:
LOW FAN - HIGH FAN - AUTO LOW FAN - AUTO
HIGH FAN
Timer
Press the TIMER button, then the TIMER button again to
adjust the ON or OFF timer in 1 hour increments. The ON
timer is set when the thermostat is in the OFF mode.  The
OFF timer is set when the thermostat is in the ON mode.
A. Cooling Operation
1. With the thermostat ON, press the MODE button until the COOL text is
lit.
2. Select a fan speed that best satisfies your need by pressing the FAN
button: Low, High, Auto Low or Auto High.
a. Low speed Continuous low fan operationSelected when room reaches
desired comfort level and needs to be maintained. Normally this low
speed is used for nighttime operation.
b. High speed - Continuous high fan speed operationSelected when
maximum cooling is required.
c. Auto low speed. Low fan cycles with the compressor.
d. Auto high speed. High fan cycles with the compressor.
3.  Set temperature to the desired level by pushing the UP or DOWN
button.
B. Gas Heat / Furnace Operation
1. Select Gas Heat by pressing the MODE button until the GAS HEAT text
is lit.
2. Set temperature to the desired level by pushing the UP or DOWN
button.
C. Dry Air Operation
1. Select the Dry Air mode by pressing the MODE button until the DRY
AIR text is lit.
2. Set temperature to the desired level by pushing the UP or DOWN
button.
3. In the dry-air mode, the Compressor & Low Fan will cycle ON and OFF
at different timing intervals depending on the setpoint.  If the
temperature is above the setpoint, the on cycle is longer than the off
INSTALLATION AND OPERATION INSTRUCTIONS FOR
RF WALL THERMOSTAT
(OPTIONAL IR REMOTE TRANSMITTER)
The remote system will give you control of both the cooling and heating
appliances from the comfort of your favorite chair.  This remote control
system has new features like ON/OFF timer, auto change over (optional
with heat appliance) and dry mode (for humidity control).
Wiring is required between the thermostat and the HVAC unit. The
thermostat wiring is field installed and must be considered before wall
paneling and ceiling panels are in place.  Wall thermostat controlled air
conditioners are normally OEM (Original Equipment Manufacturer)
installed.  Wall thermostat controlled air conditioners may be installed for
aftermarket applications, with additional considerations given to the
thermostat wire routing.
The thermostat is equipped with a 3 amp fuse that will automatically
reset.
INSTALLATION INSTRUCTIONS
BE SURE ALL ELECTRICAL POWER HAS BEEN DISCONNECTED FROM
THE AIR CONDITIONER SYSTEM AND THE POWER SUPPLY.
These instructions are provided for the proper mounting of the
thermostat itself.  An Operation Chart and Terminal Cross Reference Chart
are provided to show thermostat capabilities.
Wiring procedure is dependent upon the unit to be matched with this
component.
A.  RF Wall Thermostat Location
This thermostat is a sensitive instrument.  For accurate temperature
control and comfort, the following considerations should be taken into
account:
1. Locate the thermostat on an inside wall about five feet above the floor.
Pick a dry area where air circulation is good.  The thermostat should be
mounted within a reasonable distance from the appliance the thermostat
will control.  This will assure a more accurate temperature relationship
between the thermostat and the appliance the thermostat will control.
2. Do not install the thermostat where there are unusual heating conditions;
such as direct sunlight, heat producing appliances (television, radio, wall
lamp, etc.) or a furnace or air conditioner supply register.
B.  Routing the RF Wall Thermostat Wire Bundle
A separate wire bundle to power the 24 VAC thermostat will need to be
routed between the thermostat and the power supply.  Both 24 VAC (R) and
Common (C) must be brought up to the thermostat.
1. Route the wire bundle between the thermostat and the unit. Allow an
additional 6 inches of length at the thermostat and 12 inches at the Ac
unit.  This will give the installer the required slack necessary for wiring.
2. Route the separate 2 wire thermostat bundle between the thermostat and
the power supply.   Allow 6 inches of additional wiring on both ends.
3. If stapling the wire bundle during the routing process, be careful not to
pierce the thermostat wiring insulation.
C.  Attaching the RF Wall Thermostat
1. Separate the thermostat body from the subbase by gently pulling at the
top and bottom.
2. If this thermostat is a replacement thermostat for one which has failed or
no longer meets the needs of the system: note the thermostat wiring on
the back of the old thermostat subbase, and the system function each
wire was operating. This will save time and trouble when rewiring the
new thermostat. Before removing the thermostat wiring from the old
thermostat, make sure the power supply to the thermostat is
disconnected.
3. Attach the new thermostat subbase to the wall at the desired mounting
location.
Mount the subbase to the wall before wiring the thermostat.
DESCRIPTION
DESIG.
COLOR
24 VAC
R
Red
24 VAC - Commun
C
Blue
Low  Fan
G
Green
High Fan
GH
Grey
Compressor 1
Y1
Yellow
Compressor 2
Y2
Purple
Electric Heat
W1
White & Black
Gas Heat / Furnace
W2
White
Cool Active Reverse Valve
O
Orange
Heat Active Reverse Valve
B
Black
M o d e l 
N u m b e r
2   S ta g e  
C o o l
H e a t 
Pu m p
Ele c tr ic  
H e a t
G a s  H e a t / 
F u r n a c e
0
N O
N O
N O
N O
1
Y ES
N O
N O
N O
2
N O
Y ES
N O
N O
3
Y ES
Y ES
N O
N O
4
N O
N O
Y ES
N O
5
Y ES
N O
Y ES
N O
6
N O
Y ES
Y ES
N O
7
Y ES
Y ES
Y ES
N O
8
N O
N O
N O
Y ES
9
Y ES
N O
N O
Y ES
1 0
N O
Y ES
N O
Y ES
1 1
Y ES
Y ES
N O
Y ES
1 2
N O
N O
Y ES
Y ES
1 3
Y ES
N O
Y ES
Y ES
1 4
N O
Y ES
Y ES
Y ES
1 5
Y ES
Y ES
Y ES
Y ES
cycle to help maintain setpoint.  If the temperature is below the setpoint,
the off cycle is longer than the on cycle to help maintain setpoint.
D. Auto Change-Over Operation
1. Select the Auto Change over mode by pressing the MODE button until
the AUTO CHG text is lit.
2. Set temperature to the desired level by pushing the UP or DOWN
button.
(Note: In the Auto Change over mode the unit will maintain a comfortable
temperature throughout the room without the trouble of having to select
heat or cool mode.
E. Electric Heat Operation
1. Select Electric Heat by pressing the MODE button until the ELEC
HEAT text is lit.
2. Set temperature to the desired level by pushing the UP or DOWN
button.
3. In Electric Heat mode, if the electric heat appliance is unable to satisfy
the setpoint, the gas heat output is energized. Both gas heat and electric
heat appliances will run simultaneously until the setpoint is satisfied for
auxiliary heat.
F. Fan Only Operation
1. Fan Only operation is selected by pressing the MODE button until the
FAN ONLY text is lit.
2. Fan High or Low speeds are then selected by pressing the FAN button.
Fan will run continually at the selected speed; it is not controlled by the
setpoint.
I. Timer Operation
Note: 
Everytime the TIMER button is pressed, the display will blink for 6
seconds, alternating betwen the time and “hr”, giving the operator enough
time to start setting. If no button is pushed in 6 secs, the display will
resume showing the temperature.
1. Setting the “ON” timer:
a) To set the “ON” timer, the unit must be OFF.
b) Set the timer by pressing the TIMER button, until the display indicates
the desired delay, in hours, to turn the unit ON.
c) Wait 6 secs until the selection is stored. Display wil resume showing
room temperature.
2. Setting the “OFF” timer:
a) To set the “OFF” timer, the unit must be ON.
b) Set the timer by pressing the TIMER button, until the display indicates
the desired delay, in hours, to turn the unit OFF.
c) Wait 6 secs until the selection is stored. Display wil resume showing
room temperature.
After set, a timer will repeat its operation each 24 hours.
To turn a timer OFF, select “0” hours for the delay time.
The RF Wall Thermostat can be also controlled by a Z-Wave RF Remote
Controller or an IR Handheld Remote.
FCC
Class B Device Statement: (Section 15.105 (b) of the FCC Rules)
“Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with the instructions
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
• 
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
• 
Consult the dealer or an experienced radio/TV technician for help.