Additional information from this row can be found in the following forms:  
- Mute Symbol.  Will show on the VU screen for a linked, muted 
microphone.   
- VU or Gain Meters.  VU screen shows a VU meter for a linked, unmuted 
microphone, while the Gain screen meters look the same, but do not change 
unless set, and appear for all linked microphones.   
- RF Meters.  The RF screen will display the strength of the transmission 
from any linked microphone as it is received by the base.  Microphones 
experiencing interference or far away will have a lower RF.   
 
The second row displays battery information when seen on the VU and RF 
screens, using the following icons: 
- For a linked microphone, the battery level icon will show the charge level 
by the amount of black in the battery.   
- While in the charger, the battery symbol also shows a charging symbol 
overlaid over the battery-charge icon
2
.   
- A microphone using a permanent cross-over adapter will be shown with 
a power connector battery symbol.  A permanent cross-over adapter is one 
where the microphone does not use batteries.   
- A battery symbol with a +/- indicates a non-rechargeable battery or 
wrong battery type.  Such a battery will not charge when placed in the charger 
tray.   
 - The type of a battery is only determined when the microphone is placed 
in a charger after inserting a new battery.  Up until this time the battery 
symbol will show a battery with a question mark in it, indicating that the 
battery type is unknown.   
- Low battery, under 10% remaining. 
- Very low battery, under 5% remaining. 
 
On the gain screen, this row will not show battery information, instead having 
a row of digital gain “knobs” that will match the gain shown in the meters 
above them.   
- Gain knob 
 
 
                                            
2
 It might take a few minutes for the charge symbol to appear after a microphone was placed in 
the charger.