Installation / Operation Manual                               HotShot MH-35 RF 
 
Troubleshooting  
Indication  
Meaning  
Action  
In automatic mode, the unit works 
for 30-45 seconds without spraying 
and turns off.  
The washer lines are empty.  
Prime unit by operating the washer 
system manually until the first 
spray.  
Unit does not turn on.  
No power to unit.  
Check fuse and power connections.  
In manual priming there is no spray.   The check valve direction is 
incorrect.  
Reverse direction and retry.  
Auto LED Light Blinks (Once every 
3 seconds) 
HotShot is operating in automatic 
mode.  
No action required.  
Standby LED Light Blinks (Once 
every 3 seconds)  
HotShot is operating in standby 
mode.  
No action required.  
Both LED Lights Blink alternately 
for 6 seconds 
The blinking light indicates an 
absence of washer fluid coming into 
MH-35 RF unit, or system error.  
First check the fluid level in the 
washer fluid reservoir. Top off if 
needed. Reset the system by turning 
the unit off and on. If this fails to 
correct the condition, discontinue 
use of the unit and refer to Technical 
Support for assistance.  
The Spray is not hot.  
Blown fuse 
Discontinue use of the unit and refer 
to Technical Support for assistance.  
The washer spray was ok before the 
HotShot installation but now is 
weak.  
The hoses that connect to the inlet 
and outlet hose barbs may not be 
connected properly.  
Check the connection hoses.  
The HotShot unit starts working 
without pushing the button.  
There is a system error.  
Discontinue use of the unit and refer 
to Technical Support for assistance.  
The MH-35 RF unit has detected 
that the power supply is less than 
12.4 volts, indicating the ignition 
switch is in the “off” position, or the 
vehicles electrical system is 
overloaded.  
Make sure vehicles ignition switch 
is on. If it is, Discontinue use of the 
unit and refer to Technical Support 
for assistance.  
No connection to the vehicle’s 
battery and/or the FOB batteries are 
dead. 
Check positive and negative cables 
connections and the FOB .  
Positive battery cable in-line fuse is 
open.  
Check fuse and connections. If fuse 
is open, replace. If it pops the fuse 
again, contact technical support.  
Nothing happens when the FOB 
switch in pressed.  
MH35-RF not married to FOB 
properly.  
Check connections, connect 
properly if necessary. And re-
commission the FOB to the 
underhood unit 
The MH-35 RF begins working but 
stops operating abruptly.  
System must be at least 12.5 volts to 
operate.  
Check charging system.