SysName - An administratively-assigned name for this managed node. 
 
SysLocation - The physical location of this node. 
 
Note: 
Specifying one of these values via the Device's Web-Based Utility makes the corresponding object 
read-only. If there isn't such a config setting, then the write request will succeed (assuming 
suitable access control settings), but the new value would be forgotten the next time the agent was 
restarted.   
 
Get Community - Enter the community name that allows Read-Only access to the Device's 
SNMP information. The community name can be considered a group password. The default 
setting is “
public”.   
 
Get Source - Get source defines the IP address or subnet for management systems that can 
read information from this 'get' community device. 
 
Set Community - Enter the community name that allows Read/Write access to the Device's 
SNMP information. The community name can be considered a group password. The default 
setting is “
private”.   
 
Set Source - Set source defines the IP address or subnet for management systems that can 
control this 'set' community device. 
 
Note: 
A restricted source can be a specific IP address (e.g. 10.10.10.1), or a subnet - represented as 
IP/BITS (e.g. 10.10.10.0/24). If an IP Address of 0.0.0.0 is specified, the agent will accept all 
requests under the corresponding community name.   