Biometrx Inc. GDOB1 Manuale Utente

Pagina di 2
smart
TOUCH
Finger Activated
Garage Door Opener
USER MANUAL
Included in Box:
• Programmer
• Relay 
• Sensor Unit 
• Power Supply
• 2 Paper Drill templates
• 4 Mounting Screws 
• Cat-3 2-Wire Cable (20 ft.)
• 2 locking brackets
Hardware Required
for Installation:
• (4) #6 self taping screws
• 2 drill templates 
• Philips head screwdriver    
  (not supplied)
• 20 feet of installation cable 
  included 
WA R N I N G
To prevent possible serious injury or death from a moving gate or garage door:
 - Always keep remote controls out of reach of children.  Never permit children to 
operate, or play with remote control transmitters.
 - Activate gate or door only when it can be seen clearly, is properly adjusted, and there 
are no obstructions to door travel.
 - Always keep gate or garage door in sight until completely closed.  Never permit 
anyone to cross path of moving gate or door.
Step 1
Pairing Relay to 
Sensor Unit
RECOMMENDED
Perform on flat surface before mounting.
A) Remove the programmer, relay and sensor unit from box   
B) Connect relay unit to power supply
C) Remove battery door on sensor unit 
   - Install 4 AAA batteries (not included)
D) Connect programmer to sensor unit (powers up
only when connected to sensor)
E) Open cover of sensor unit
    - Green LED light will display on
      both sensor and relay units
F) Press OK on programmer
    Note:  Ensure sensor unit and relay 
                  are at least 3 feet apart
G) Enter set–up mode
    - Follow prompts on LCD display  
      [Observe relay for required feedback]
    - Pair sensor unit to relay    
Once pairing is complete, you will be prompted to define administrator.
 
 
 
 
 
 
   
Step 2
Enrollment
Define Administrators
A) Connect programmer to sensor unit
B) Lift sensor unit cover.  Sensor unit will display green LED light
C) Press “OK” on programmer
Note:  3 successful swipes are required to complete enrollment.
  - Follow programmer prompts to enroll administrator
  - Programmer will advise “looking for image” and “processing image” after finger swiped 
  - “Processing image” indicates 3 successful swipes accepted
D) When prompted, please choose a 4 digit pin number
     - Press CAN to go back to previous page
As an administrator, you can add or delete other administrators or access 
users.  Follow enrollment process to add and delete users as needed.
 If during enrollment programmer freezes/powers off - disconnect 
programmer, close sensor unit cover, reconnect programmer, open sensor 
unit cover and proceed to enrollment
Step 3
Test Units 
Once administrator is enrolled, proceed to test units
A) Close sensor unit cover
B) Disconnect programmer from sensor unit
C) Open sensor unit cover
D) Swipe previously accepted finger again
    - Relay will flash green and click
E) Remove power supply from relay unit and proceed to installation
Note:  If test fails (relay unit doesn’t flash and click simultaneously) 
proceed to Factory Reset and pair units again.
How to Swipe Finger
Note
A solid green LED indicates sensor unit is ready to accept finger swipe
Swipe the pad of your finger firmly over the sensor in slow and steady 
motion.  Sensor unit provides feedback if swipe is accepted.  Flashing 
red LED swipe indicates unsuccessful read.  Green LED blinks twice, 
turns off and returns to solid state if swipe is successful.  
 
 
       
 NOTE:   When programmer is connected during unit 
 
 
            administration LCD display will indicate “bad  
 
 
            swipe”.
 
 
        Reasons for unsuccessful swipe:
 
 
          
  o Wrong finger swiped       o Finger swiped too fast
 
 
            o Finger swiped too slow    o Inaccurate finger placement 
Select a mounting location. 
Step 5
Install Sensor Unit
A) Select mounting location for sensor unit outside of garage
B) Test to ensure sensor unit is within relay range
C) Tape sensor unit drill template to the desired location
D) Mark center of 2 mounting eyelets on wall 
E) Install the two mounting screws on the wall where marked
F) Leave 1/10 inch gap between screw and wall
G) Insert locking brackets to first line (with tabs facing front of sensor unit)
H) Mount sensor on wall,  aligning mounting screw heads with mounting eyelets
I) Slide sensor unit down on to screws and push in locking brackets till flush
Factory Reset
Sensor Unit
- Connect programmer to sensor unit
- Lift sensor unit cover
- Swipe  enrolled administrator finger to access administrator menu
- Select “5” – system  -->  Select “3” – factory reset  -->
   Press “1” – to accept factory default reset 
-  Press “1” – to accept default 
- Programmer will indicate programmer factory default accepted 
- Close sensor unit cover
- Remove programmer from sensor unit 
Relay Unit
- Press and hold learn button
- LED light will turn off 
- Continue holding learn button down until light turns on again
- Disconnect power from relay unit for 10 seconds and then reconnect
- Relay unit successfully reset
Note:  In order to use the sensor and relay unit, you must pair again. 
Note
Can only be performed by administrative user
mini USB
 port
LED
display
swipe 
sensor
sensor unit
cover
channel
guide
Sensor Unit
Trouble Shooting Guide
Step 4
mounting
eyelets
locking
tab
battery
door
Install Relay Unit
back
top
Relay Unit
front
top
righ
t
learn
switch
push
button
power
port
back
wire
channel
mounting
eyelets
terminal
screws
Programmer
1
2
3
4
5
6
7
8
9
0
OK
CAN
LCD
display
keypad
mini-USB
cable
Power Supply
1
2
3
4
5
6
7
8
9
0
OK
CAN
Follow Me...
Note
We recommend you disconnect power to opener before performing this step.
    -Tape relay drill template to mounting surface
    -Mark center of 2 mounting eyelets on wall
    -Install screws into walls at marked points. Leave 1/10th inch gap between     
     screw head and wall
Replacing Existing Switch   
Remove existing wall switch and connect 2 existing wires to terminal screws on 
back of relay unit 
    -Loosen terminal screws on back of relay unit.  2 wires must be stripped 
      approx. 3/4 inches
    -Bend end of wires to hook around screw heads
    -Once wires catch around screws, tighten screws and ensure wires are secure.
*DO NOT ALLOW WIRES TO TOUCH OPPOSITE SCREW TERMINAL
    -Mount relay unit on wall by aligning mounting screws with mounting eyelets
Not Replacing Existing Switch
    -Run wires from the top of your existing garage door opener to desired 
     location.   20 ft. cable is included, more might be needed
    -Connect 2 wires to terminal screws on back of relay as before
    -Mount relay unit on wall as before
If Relay is on Top of Opener Mechanism
    -Cut cable to desired length (20 ft. included) connect wires to terminal screws 
      on back of relay unit
    -Affix relay to top of garage door opener.  Velcro or double sided tape can be      
      used (not included). 
Connect Relay to Opener Mechanism 
    - Connect wires to 2 “dry contact” terminals on garage door opener mechanism
   - We recommend disconnecting power from garage door opener mechanism 
     prior to connecting relay
    Note:  Refer to relay wiring guide on back of manual
Ensure that the sensor unit and relay are at least 3 feet apart.  Relay can be 
mounted on top of garage door mechanism or wall mounted to replace or in 
addition to existing push button. 
Garage Door doesn’t open when finger is swiped: 
    - Verify accurate finger swipe (see “How to Swipe Finger”)
    - Ensure you are using previously enrolled finger
    - Test push button on relay to open/close garage door
Intermittent red flash on sensor unit 
    - Batteries are low.  Change batteries and try again.  
If this doesn’t work: 
Connect programmer to sensor unit for more 
trouble shooting features.
If this doesn’t work: 
check for loose wires on relay.  
Ensure wires are securely connected to terminal screws on back of relay 
unit and on dry contact switch connectors on garage door opener 
mechanism.  
Programmer does not turn on:
Remove 4 screws on back of programmer and replace coin cell battery
If unit still does not work: 
visit us on the web or call customer service. 
1 (866) 9 NO-KEYS
www.bioMETRX.net/support
Programmer may display:
- Low Battery – change batteries and try unit again
For the following errors, follow instructions below:
- Sensor Error       - App. Error           - App. Data                  - Data Error 
- Ram Error           - Comm. Error     - Ram Comm. Error 
-  Close sensor cover and re-open again.  
If this doesn’t work:
 
Remove unit from wall.
Remove battery door  and remove one battery.  
Replace battery, secure battery door and sensor unit cover.  
Try sensor unit again.
If  garage  door  still  doesn’t  open: 
 
follow  instructions  to 
factory reset then pair units again. 
top
rig
h
t
learn
switch
How to Operate
To open / close 
garage door
 - Lift sensor cover 
 - Swipe enrolled 
   finger
or 
 - Push button on
   relay unit
Note:  
Sensor unit has 
30 second power save 
feature – close sensor 
cover and re-open to 
reactivate sensor unit. 
T H I S   D E V I C E   C O M P L I E S   W I T H   P A R T   1 5   O F   T H E   F C C   R U L E S .   O P E R AT I O N  
I S   S U B J E C T   T O   T H E   F O L L O W I N G   T W O   C O N D I T I O N S :   ( 1 )   T H I S   D E V I C E  
M AY   N O T   C A U S E   H A R M F U L   I N T E R F E R E N C E ,   A N D   ( 2 )   T H I S   D E V I C E   M U S T  
A C C E P T   A N Y   I N T E R F E R E N C E   R E C E I V E D ,   I N C L U D I N G   I N T E R F E R E N C E  
T H AT M AY   C A U S E   U N D E S I R E D   O P E R AT I O N .
N O T E :       T H E   M A N U F A C T U R E R   I S   N O T   R E S P O N S I B L E   F O R   A N Y   R A D I O   O R  
T V   I N T E R F E R E N C E   C A U S E D   B Y   U N A U T H O R I Z E D   M O D I F I C AT I O N S   T O  
T H I S   E Q U I P M E N T .   S U C H   M O D I F I C AT I O N S   C O U L D   V O I D   T H E   U S E R ’ S  
A U T H O R I T Y   T O   O P E R AT E   T H E   E Q U I P M E N T .
Specifications:
• Programmer
     1 coin cell battery CR2032
• Sensor Unit
   
Requires 4 AAA alkaline batteries (use of lithium 
     batteries will void warranty)
     Operates from –20º C to +50º C (-4ºF to 122ºF)
     Power Supply – Input 100 – 240V
                                    Output DC 5V – 1A
     Operating frequency - 433.9Mhz
First Line
tab
locking
bracket