BandRich Inc. 35K888 Manuale Utente

Pagina di 91
Appendix A: Vehicle Installation Guide 
70
 
 
2.  Use the proper wire size according to the expected current load. 
Please see the table below: 
 
AWG Rating 
Electric Current 
Load (Amps) 
10-Feet Cable 
20-Feet Cable 
3-10 
14 AWG 
12 AWG 
11-20 
14 AWG 
10 AWG 
21-35 
8 AWG 
6 AWG 
3.  To avoid problems caused by corrosion and other imperfections, use a 
dedicated ground wire instead of direct attachment to chassis ground. 
4.  To minimize noise interference, implementation of isolation or filters 
among the router and other electrical devices is recommended. 
5.  Ensure that your K530 is securely mounted on the vehicle. In addition 
to electrical requirements, also consider vibration and temperature 
factors when choosing the optimal location for mounting your K530. If 
vibration problem is noticeable, anti-vibration rubber grommets may 
be used to reduce shock on your K530. Also avoid mounting your 
K530 near a spot subject to extreme heat, such as a poorly ventilated 
spot that is near the engine or is prone to direct sunlight.